Godrej AC Error Codes & Troubleshooting Guide [India]

TL;DR: Common Causes of Godrej AC Error Codes
Inverter Godrej Split AC Error Codes
| Error Codes & Meaning | Quick Solutions |
|---|---|
| EE – Indoor machine EE fault | Restart the unit. If error continues, indoor PCB needs professional inspection. |
| E1 – Indoor fan fault | Check nothing blocks the indoor fan. Restart AC. Call technician if it repeats. |
| E2 – Indoor fan zero-crossing detection abnormal | Restart AC. If code stays, indoor PCB needs technician check. |
| E3 – Indoor coil fault and sensor fault | Restart unit. Clean the filter and coil. Persistent error needs technician visit. |
| E4 – Indoor ambient temperature sensor fault | Power cycle the AC. If error returns, sensor replacement is required. |
| E0 – Outdoor EE fault | Restart the unit. If fault persists, outdoor PCB memory needs technician check. |
| E6 – Indoor and outdoor communication fault | Check wiring between indoor and outdoor units. Restart AC. Call technician if unresolved. |
| E8 – Outdoor communication fault | Check wiring connections at the outdoor unit. Call technician if error persists. |
| F1 – Compressor starting abnormal (phase failure, reverse) | Check power supply and voltage. Call technician for compressor or wiring check. |
| F2 – Compressor out-of-step fault | Restart AC after a few minutes. Persistent fault needs technician diagnosis. |
| F3 – IPM module fault | Turn off AC and call a technician. This is an internal outdoor unit fault. |
| F4 – Compressor shell roof fault/protection | Turn off AC, let it cool for 30 minutes. Check outdoor unit ventilation before restart. |
| F5 – Discharge temperature sensor fault | Restart unit. If error repeats, sensor needs technician replacement. |
| F6 – Suction temperature sensor fault | Restart AC. Persistent error needs professional sensor check. |
| F7 – Outdoor coil temperature sensor fault | Check outdoor unit for dust or blockage. Call technician if error stays. |
| F8 – Outdoor ambient temperature sensor fault | Restart the unit. If unresolved, sensor replacement is needed. |
| F9 – Outdoor DC fan fault | Check outdoor fan for obstruction. Call technician if fan does not spin freely. |
Fixed Speed Godrej AC Error Codes
| Error Codes & Meaning | Quick Solutions |
|---|---|
| H6/E5 – IDU fan motor protection | Turn off AC, check nothing blocks the indoor fan, restart. Call technician if it repeats. |
| dF – Frost protection | Normal auto-defrost. If it triggers often, check filter, airflow, or refrigerant level. |
| E1 – Room sensor error | Turn off AC, wait 10 minutes, restart. If it repeats, call a technician to check the sensor. |
| E2 – Evaporator sensor error | Restart the unit. Clean the filter and coil. If error stays, sensor needs replacement. |
| U8* – Zero cross detection | Restart AC. If code stays, indoor PCB needs technician check. |
| E3* – ODU coil sensor error (in heat mode) | Restart AC. If fault continues in heat mode, call technician for sensor check. |
| HF* – ODU frost protection (in heat mode) | Normal defrost cycle. Frequent triggering needs technician inspection. |
| HP* – IDU coil over heat protection (in heat mode) | Turn off AC, let it cool, check airflow around indoor unit. Call technician if it repeats. |
* For selected models only
Hire Our Expert AC Technician for Same Day Home Service Without Advance in Kolkata
Godrej split and window ACs display error codes on the indoor unit when a sensor, fan, or compressor fault is detected, helping users spot problems early.
These differ from protection codes like dF (frost protection) or H6 (fan motor protection), which are safety cutoffs the AC triggers on its own to prevent damage, not actual faults.
This guide covers both inverter and fixed speed Godrej Split and Window AC models, based strictly on official Godrej user manuals, so Indian users can quickly identify the issue before deciding whether a simple restart helps or a technician visit is needed.

Godrej Fixed Speed (Non-Inverter) AC Error Code Explanation With Solutions

dF – Frost Protection
What Causes This Error: The AC’s frost protection feature activates when the evaporator coil gets too cold, usually due to low airflow, a dirty filter, or low refrigerant.
How to Fix The Error: Turn off the AC, clean or replace the filter, and check that airflow is not blocked. If frost keeps forming, call a technician to check the refrigerant level.
E1 – Room Sensor Error
What Causes This Error: This appears when the room temperature sensor is short-circuited or has an open connection, so the AC cannot read the room temperature correctly.
How to Fix The Error: Restart the AC after 10 minutes. If the error returns, a technician needs to inspect or replace the room sensor.
E2 – Evaporator Sensor Error
What Causes This Error: This occurs when the evaporator coil sensor is short-circuited or open, preventing accurate coil temperature readings.
How to Fix The Error: Restart the unit and clean the filter and coil. If the error persists, the sensor likely needs replacement by a technician.
E3 – Condenser (Outdoor Coil) Sensor Error (Heat mode only)
What Causes This Error: This happens when the condenser coil sensor is short-circuited or open, mainly noticed during heat mode operation.
How to Fix The Error: Restart the AC and check the outdoor unit is not blocked or dusty. Persistent errors need a technician visit for sensor replacement.
E5 / H6 – Indoor Fan Motor Protection
What Causes This Error: This triggers when the indoor fan motor has a fault, causing the compressor and fan to shut off immediately as a safety measure.
How to Fix The Error: Turn off the AC, check nothing is blocking the indoor fan, and restart. If the fan does not spin freely, call a technician to check the motor.
U8 – Zero Cross Detection (Selected models only)
What Causes This Error: This code appears when the AC’s zero-crossing detection circuit, used for fan speed control, malfunctions.
How to Fix The Error: Restart the AC. If the code continues to appear, the indoor PCB needs professional inspection.
HF – Outdoor Unit Frost Protection (Heat mode only, selected models only)
What Causes This Error: This is a normal protection response when the outdoor coil frosts up during heat mode operation.
How to Fix The Error: This is usually part of the normal defrost cycle. If it triggers too often, have a technician inspect the outdoor unit.
HP – Indoor Coil Overheat Protection (Heat mode only, selected models only)
What Causes This Error: This activates when the indoor coil overheats during heat mode, often due to restricted airflow.
How to Fix The Error: Turn off the AC, let it cool, and check for blocked airflow around the indoor unit. Call a technician if the issue repeats.
Godrej Inverter AC Error Code Explanation With Solutions

Indoor Unit
EE – Indoor Machine EE Fault
What Causes This Error: Indicates an internal memory (EEPROM) fault in the indoor unit’s PCB.
How to Fix The Error: Restart the unit. If the error continues, the indoor PCB needs professional inspection.
E1 – Indoor Fan Fault
What Causes This Error: Occurs when the indoor fan motor is obstructed or malfunctioning.
How to Fix The Error: Check nothing blocks the indoor fan and restart the AC. Call a technician if it repeats.
E2 – Indoor Fan Zero-Crossing Detection Abnormal
What Causes This Error: Happens when the fan speed detection circuit fails to read signals correctly.
How to Fix The Error: Restart the AC. If the code stays, the indoor PCB needs a technician check.
E3 – Indoor Coil Fault / Indoor Coil Sensor Fault
What Causes This Error: Triggered when the indoor coil sensor is faulty or the coil itself has an issue.
How to Fix The Error: Restart the unit and clean the filter and coil. Persistent errors need a technician visit.
E4 – Indoor Ambient Temperature Sensor Fault
What Causes This Error: Appears when the room ambient temperature sensor is short or open.
How to Fix The Error: Power cycle the AC. If the error returns, the sensor needs replacement.
E6 – Indoor & Outdoor Unit Communication Fault
What Causes This Error: Caused by a broken signal, damaged wiring, or connector issue between indoor and outdoor units.
How to Fix The Error: Check the wiring between both units and restart the AC. Call a technician if unresolved.
Outdoor Unit
E0 – Outdoor EE Fault
What Causes This Error: Indicates an internal memory (EEPROM) fault in the outdoor unit’s PCB.
How to Fix The Error: Restart the unit. If the fault persists, the outdoor PCB needs a technician check.
E8 – Outdoor Communication Fault
What Causes This Error: Occurs due to a break or fault in the communication line at the outdoor unit.
How to Fix The Error: Check wiring connections at the outdoor unit. Call a technician if the error persists.
F1 – Compressor Starting Abnormal (Phase Failure / Reverse Phase)
What Causes This Error: Happens when the compressor fails to start due to phase failure or reversed wiring.
How to Fix The Error: Check the power supply and voltage. A technician should check the compressor wiring.
F2 – Compressor Out-of-Step Fault
What Causes This Error: Occurs when the compressor motor loses synchronization during operation.
How to Fix The Error: Restart the AC after a few minutes. Persistent faults need technician diagnosis.
F3 – IPM Module Fault
What Causes This Error: Indicates a fault in the outdoor unit’s Intelligent Power Module, which controls the compressor.
How to Fix The Error: Turn off the AC and call a technician, as this is an internal outdoor unit component fault.
F4 – Compressor Shell Temperature Protection / Shell Roof Fault
What Causes This Error: Triggers when the compressor shell overheats beyond a safe limit.
How to Fix The Error: Turn off the AC and let it cool for 30 minutes. Check outdoor unit ventilation before restarting.
F5 – Discharge Temperature Sensor Fault
What Causes This Error: Occurs when the sensor monitoring the compressor’s discharge temperature fails.
How to Fix The Error: Restart the unit. If the error repeats, the sensor needs technician replacement.
F6 – Suction Temperature Sensor Fault
What Causes This Error: Happens when the sensor monitoring the suction line temperature is short or open.
How to Fix The Error: Restart the AC. Persistent errors need professional sensor inspection.
F7 – Outdoor Coil Temperature Sensor Fault
What Causes This Error: Triggered when the outdoor coil temperature sensor malfunctions.
How to Fix The Error: Check the outdoor unit for dust or blockage. Call a technician if the error stays.
F8 – Outdoor Ambient Temperature Sensor Fault
What Causes This Error: Occurs when the sensor reading outdoor ambient temperature is faulty.
How to Fix The Error: Restart the unit. If unresolved, the sensor needs replacement.
F9 – Outdoor DC Fan Fault
What Causes This Error: Happens when the outdoor DC fan motor fails to run correctly.
How to Fix The Error: Check the outdoor fan for obstructions. Call a technician if the fan does not spin freely.
Urban Service Plaza is the best Godrej Service Centre in Kolkata for expired warranty products. Hire our technicians for same day appliance repair at your doorstep.
Troubleshoot for Most Common Godrej AC Problems

AC does not operate immediately after being restarted
This happens because the compressor has a built-in overload protection delay. It is completely normal, and the AC will restart on its own after about 3 minutes.
Unusual smell coming from the indoor unit
The AC itself does not produce odors. The smell usually comes from dust, smoke, furniture, or other odors that have accumulated inside the unit. Clean the air filter, and if the odor persists, have the indoor unit professionally cleaned by an authorized service center.
Water-flow or gurgling sound during operation
This sound is caused by refrigerant flowing inside the system as the compressor starts, stops, or operates. It is a normal operating condition and does not need any action.
Mist coming out of the air outlet in Cool mode
This can happen when room temperature and humidity are very high, causing rapid cooling of room air to condense into mist. Continue operating the AC, and the mist will disappear as room temperature and humidity decrease.
Creaking or cracking noise when the AC starts or stops
This noise is caused by plastic components inside the unit expanding and contracting due to temperature changes. It is normal and does not indicate a fault.
The air conditioner does not run
Check whether the power supply has been switched off, the plug is loose, or the circuit breaker or fuse has tripped. Also verify the supply voltage is not too high or too low, and confirm the TIMER function has not been set incorrectly.
Cooling or heating performance is poor
Check that the temperature setting is appropriate, the fan speed is not too low, and the indoor and outdoor vents are not blocked. Dirty filters, open doors or windows, and heat sources inside the room can also reduce performance.
Wireless remote control does not work
Unplug the AC, wait briefly, and reconnect the power, as electrical interference can temporarily affect the remote. Also check that the remote is within range, its batteries are not weak, and it is not physically damaged.
Water leaking from the indoor unit
This can happen due to high indoor humidity causing condensation, condensate water overflow, or a loose or disconnected drain pipe connection. Check the drain pipe connection first, and contact a technician if the leak continues.
Water leaking from the outdoor unit
This is usually caused by condensation on refrigerant pipes during cooling, melted frost during automatic defrost, or condensed water from the outdoor heat exchanger during heating. These conditions are generally normal and do not need any action.
Noise coming from the indoor unit
Clicking sounds may come from the fan or compressor relay switching on and off, while refrigerant flow and fan noise can occur during defrost operation. These are normal operating sounds and do not indicate a fault.
Indoor unit does not blow air (Heat & Cool models only)
In HEAT mode, the indoor fan stays off until the heat exchanger warms up, usually within about 2 minutes. During automatic defrost, the fan may stop for 3 to 12 minutes, and it may pause briefly in Dry mode to prevent condensed water from evaporating back into the room.
Moisture on the air outlet vent
When the AC runs for a long time in high humidity, moisture may condense on the air outlet grille and drip. This is normal and does not require any action.
When to Call Godrej Service Centre for Technician Visit?
Godrej AC error codes help you spot problems early, before they turn into bigger repairs. Start with simple steps like a power reset, filter cleaning, and airflow checks.
Avoid repeated restarts for compressor, PCB, or voltage-related codes, as this can worsen the fault. If the same error returns or the AC still malfunctions, contact Godrej service centre for professional diagnosis.