Whirlpool AC Error Codes & Troubleshooting Guide [Finder Tool]

Whirlpool AC showing an error code? Use our error finder tool to see what it means, get troubleshooting steps, and know when to call an AC expert. Free checklist included.

Whirlpool AC error codes

Whirlpool AC Error Codes at a Glance

  • This guide covers Whirlpool inverter split AC error codes, including the E, F, P, and L series, plus outdoor unit LED blink codes.
  • Check your indoor display for a direct code, or count the outdoor unit’s LED blinking pattern if no code shows indoors.
  • Most errors fall into 4 categories: sensor faults, communication errors, PCB or voltage issues, and refrigerant problems.
  • Sensor and communication errors often clear with a simple power reset (5–10 minutes).
  • PCB, voltage, and refrigerant errors usually need a trained technician to diagnose safely.
  • Use the table below to find your code, or call Urban Service Plaza for same-day diagnosis in Kolkata.

Whirlpool AC error codes appear on your indoor display, or as blinking LED patterns on the outdoor unit, whenever the system detects a malfunction. These alphanumeric codes act as an early warning system, flagging problems before they cause bigger damage.

An error code points to a faulty system, not always the exact broken part. Some causes are simple, like loose wiring or a dirty sensor. Others, like PCB or refrigerant issues, need a trained technician. This guide gives you the full error code table, common causes, safe DIY checks, and clear signs of when to call a professional.

trusted source google

Whirlpool AC Error Finder Tool

Choose how your AC is showing the fault, then find out what it means.

Error Code
LED Blinking

Whirlpool AC Error Code Chart: Meaning & Quick Solutions

Here is a quick-scan chart of all major Whirlpool inverter AC error codes and their fixes.

Error CodeWhat It MeansQuick Fix / Next Step
UAIndoor and outdoor unit mismatchConfirm matching model/capacity, replace mismatched unit
E6Indoor-outdoor communication failureCheck wiring, power supply, inspect PCB
PLOutdoor DC voltage too lowMeasure DC voltage, repair/replace inverter PCB
PHOutdoor DC voltage too highCheck DC output, repair/replace inverter PCB
F0 / P0Refrigerant shortage or blocked flowCheck pressure, inspect for leaks, recharge gas
P7Indoor temperature sensor faultCheck wiring, measure resistance, replace sensor
F2Indoor coil/pipe sensor faultReconnect sensor, check refrigerant, replace if faulty
F3Outdoor ambient sensor faultClean sensor, check wiring, replace if defective
F4Outdoor condenser sensor/compressor faultCheck sensor, fan, refrigerant, and compressor
F5Compressor discharge sensor faultClean sensor, check wiring, replace if defective
F6Outdoor suction temperature sensor faultCheck wiring, measure resistance, replace sensor
F7Outdoor ambient/condenser coil sensor faultCheck wiring, replace sensor or outdoor PCB
F8Outdoor ambient sensor faultInspect sensor and wiring, replace if defective
F9Outdoor DC fan motor faultCheck motor, wiring, voltage; replace fan motor
E0Outdoor PCB faultVerify power supply, repair/replace outdoor PCB
E1Indoor fan motor faultCheck blower, wiring, PCB output; replace fan motor
E3Indoor coil/gas pipe sensor faultInspect sensor, measure resistance, replace sensor
E4Indoor room temperature sensor faultCheck wiring, measure resistance, replace sensor
EEIndoor PCB faultCheck fan/sensors first, repair/replace indoor PCB
H6Indoor fan feedback failureCheck fan wiring, replace fan motor or inspect PCB
P5System overload protectionCheck refrigerant, outdoor fan, compressor current
P6Startup failureVerify voltage, wiring, and indoor/outdoor PCBs
P8Four-way/reversing valve faultCheck valve coil, replace valve if faulty

Outdoor LED Blink Codes (No Indoor Display)

For units without a code display, count the LED blink pattern on the outdoor unit.

LED1LED2LED3Fault
XXXNormal operation
★X★Outdoor coil temperature sensor fault
★XXCompressor exhaust temperature sensor fault
XXâ—‹Indoor-outdoor communication failure
★○XCurrent overload protection
★○★Maximum current protection
★★★Outdoor EEPROM fault
X○★Compressor exhaust temperature too high
★★XOutdoor ambient temperature sensor fault
X★○Compressor shell temperature too high
Xâ—‹â—‹Anti-freeze/overload protection (indoor unit)
â—‹Xâ—‹Compressor drive fault
○○★Outdoor fan motor locked rotor
X★XOutdoor coil anti-overload protection
Xâ—‹XIPM module protection
â—‹XXPFC protection
★★○AC voltage higher/lower protection
â—‹â—‹XDC compressor start failure
★○○Outdoor ambient temp too low/high

★ = Light on, ○ = Flashing, X = Off






    *We do not claim copyright over the logos and brand names used on our website; they are used for illustration purposes only. See disclaimer.

    How to Identify the Error Code on Your Whirlpool AC?

    whirlpool ac

    Whirlpool inverter ACs show faults in two ways. Newer models display a direct alphanumeric code on the indoor unit, while others use a blinking LED pattern on the outdoor unit’s PCB. Follow these steps to find yours:

    1. Check the indoor unit display first for a direct alphanumeric code, such as E6, F2, PL, or UA.
    2. If there is no indoor display code, open the outdoor unit and locate the three LEDs (LED1, LED2, LED3) on the PCB.
    3. Note whether each LED is steady ON (★), flashing (○), or OFF (X).
    4. Match the ON, OFF, and flashing combination to the LED blink pattern table in the chart above to find the exact fault.
    5. Write down the exact code or pattern before power-cycling the unit, since some faults clear on restart and become harder to diagnose later.

    If you need prompt same day service contact Urban Service Plaza, the best Whirlpool AC service centre in Kolkata for out of warranty products. No advance charges and 15 days service guarantee.

    Whirlpool AC Error Codes Explained: Causes and Step-by-Step Fixes?

    UA – Setting Error (Indoor & Outdoor Unit Mismatch)

    Possible Causes

    • The indoor and outdoor units are not the same model or capacity, which prevents them from working together correctly.
    • Incorrect pairing happened during the original installation, linking units that were never designed to match.

    What to Do

    • Verify that both the indoor and outdoor units share the exact same model and capacity rating.
    • If a mismatch is confirmed, the incorrect unit will need to be replaced with a matching one.

    E6 – Communication Failure

    Possible Causes

    • The indoor and outdoor units have lost communication with each other, often due to a faulty communication cable.
    • One of the two PCBs (indoor or outdoor) may not be receiving power, or the PCB itself may have failed.

    What to Do

    • Check that both indoor and outdoor PCBs are receiving proper power supply.
    • Inspect the communication wiring for loose, broken, or incorrectly connected wires, and measure the communication voltage, which should typically read 13–24 VDC.
    • If voltage is missing at the indoor PCB, inspect it directly; if the indoor output is normal but the outdoor unit shows no signal, inspect or replace the outdoor PCB.

    Voltage & Power Supply Errors (PL, PH)

    PL – DC Input Voltage Too Low

    Possible Causes

    • The outdoor inverter PCB is failing to supply the correct DC voltage to the system.

    What to Do

    • Measure the DC voltage coming from the inverter PCB and inspect its output to the compressor and fan motor.
    • Repair or replace the outdoor inverter PCB if the voltage reading stays low.

    PH – DC Input Voltage Too High

    Possible Causes

    • The inverter PCB is supplying excessively high DC voltage to the system.

    What to Do

    • Check the DC voltage output and inspect the inverter PCB for damage.
    • Repair or replace the faulty PCB, since incorrect voltage can damage other components.

    Refrigerant-Related Errors (F0/P0)

    F0 (or P0 on some models) – Refrigerant Shortage / Flow Protection

    This error signals a refrigerant leak, low gas charge, or blocked refrigerant flow inside the system. Whirlpool ACs trigger this code to protect the compressor from running without proper cooling gas.

    Possible Causes

    • Refrigerant leakage or a low refrigerant charge.
    • A blocked capillary tube or restricted refrigerant piping.

    What to Do

    1. Check the refrigerant pressure using proper gauges.
    2. Inspect the entire system for leaks.
    3. Check for any blockage in the capillary tube or copper piping.
    4. Flush and vacuum the refrigerant lines before recharging.
    5. Recharge the refrigerant strictly to the manufacturer’s specifications.
    6. If you are from Kolkata or nearby areas, contact us for a low cost AC gas refilling service.

    Sensor Fault Errors (P7, F2, F3, F4, F5, F6, F7, F8)

    CodeSensor AffectedCommon CauseFix
    P7Indoor temperature sensorFaulty sensor, loose connection, or damaged wiringCheck wiring, measure resistance, replace sensor if defective
    F2Indoor coil/pipe sensorSensor malfunction or disconnection after servicingReconnect sensor, verify position, check refrigerant level
    F3Outdoor ambient sensorDamaged, dirty, or disconnected sensorClean sensor, check wiring, replace if defective
    F4Outdoor condenser sensor / compressorSensor fault, compressor overheating, or low refrigerantCheck sensor, fan operation, and refrigerant charge
    F5Compressor discharge sensorSensor failure or damaged wiringClean sensor, check wiring, replace if defective
    F6Outdoor suction sensorSuction pipe sensor malfunctionCheck wiring, measure resistance, replace faulty sensor
    F7Outdoor ambient/condenser coil sensorSensor malfunction (model dependent)Verify placement, measure resistance, replace sensor
    F8Outdoor ambient sensorSensor failureInspect sensor and wiring, replace if defective

    Most sensor faults can be checked at home by cleaning the sensor and inspecting the wiring for damage. However, resistance testing and sensor replacement need a trained technician to avoid further PCB damage.

    If you are not confident anough for fixing the Whirlpool AC by yourself, immidiately contact us for AC repairing service in Kolkata & nearby areas without any advance booking charges.

    Fan Motor & PCB Errors (E0, E1, E3, E4, EE, H6, F9)

    CodeComponent AffectedCommon CauseFix
    E0Outdoor PCBOutdoor control board malfunctionVerify power supply, repair or replace outdoor PCB
    E1Indoor fan motorMotor failure or jammed blowerEnsure blower rotates freely, check wiring, replace motor
    E3Indoor coil/gas pipe sensorSensor malfunctionInspect sensor, measure resistance, replace if faulty
    E4Indoor room temperature sensorSensor failureCheck wiring, measure resistance, replace sensor
    EEIndoor PCBPCB unable to communicate or provide outputVerify fan and sensors first, repair or replace indoor PCB
    H6Indoor fan feedbackFan RPM signal missingCheck fan wiring, replace fan motor or inspect PCB
    F9Outdoor DC fan motorFan motor failureCheck motor operation, wiring, and supply voltage

    Compressor & System Protection Errors (P5, P6, P8)

    P5 – System Overload Protection

    Possible Causes

    • The compressor is overloaded, or the outdoor fan has stopped operating correctly.
    • Low refrigerant, or the PCB is not supplying power to the compressor correctly.

    What to Do

    • Check the refrigerant charge and verify that the outdoor fan is operating normally.
    • Inspect the compressor current and check the inverter PCB outputs for faults.

    P6 – Startup Failure

    Possible Causes

    • The compressor or system fails to start due to a communication issue between units.
    • Low mains voltage or a PCB failure can also prevent startup.

    What to Do

    • Verify the input voltage and check the communication wiring between units.
    • Inspect both indoor and outdoor PCBs, and confirm the compressor is receiving proper power supply.

    P8 – Four-Way/Reversing Valve Fault

    Possible Causes

    • The reversing valve is malfunctioning, which is typically noticed while the unit runs in heating mode.

    What to Do

    • Check the four-way valve coil and verify the valve is operating correctly.
    • Replace the faulty valve or coil if testing confirms the fault.

    No Indoor Display? How to Read Whirlpool Outdoor Unit LED Error Codes

    Some Whirlpool AC models don’t show an alphanumeric code on the indoor display. Instead, they use three LEDs on the outdoor unit’s PCB to signal a fault.

    LED Status Legend

    • ★ = Steady ON
    • â—‹ = Flashing
    • X = OFF

    How to Use This Method?

    1. Open the outdoor unit and observe the three LEDs (LED1, LED2, LED3) on the PCB.
    2. Note the exact status of each LED: ON, OFF, or flashing.
    3. Match the pattern to the LED blink code table in Section 3 to identify the fault.

    Worked Examples

    • LED1 = ★, LED2 = X, LED3 = ★ → Outdoor coil temperature sensor fault
    • LED1 = X, LED2 = X, LED3 = â—‹ → Indoor-outdoor communication failure
    • LED1 = ★, LED2 = â—‹, LED3 = X → Current overload protection
    • LED1 = â—‹, LED2 = â—‹, LED3 = ★ → Outdoor fan motor locked rotor protection

    LED patterns can vary slightly by model or PCB revision, so cross-check with the sticker on the outdoor unit’s PCB cover if available.

    Which Whirlpool AC Errors Can You Fix Yourself?

    whirlpool ac

    Use this quick checklist to decide if your Whirlpool AC error needs a DIY check or a professional visit.

    You Can Try YourselfCall a Professional
    Power-cycle the unit for 5–10 minutes, then restartPCB replacement or repair (indoor or outdoor)
    Check remote batteries and settingsRefrigerant leak detection, flushing, or recharging
    Clean visible dust from sensorsCompressor or fan motor replacement
    Check for loose external wiring (only with power OFF)Voltage or inverter PCB faults (PL, PH)
    Communication wiring faults inside the unit
    Four-way valve replacement

    Final Thoughts

    Whirlpool AC error codes are a fast diagnostic tool, not just an annoying beep. Understanding them saves you time and unnecessary repair costs.

    Simple issues like loose wiring, dirty sensors, or low remote batteries can often be checked safely at home. PCB, refrigerant, and compressor faults always need certified help. Note down the exact code or LED pattern, then contact Urban Service Plaza for fast, doorstep AC diagnosis in Kolkata.