Godrej AC Error Codes & Troubleshooting Guide [India]

godrej ac error codes

TL;DR: Common Causes of Godrej AC Error Codes

  • Sensor faults – Room, evaporator, condenser, or ambient temperature sensors becoming short or open (E1, E2, E3, E4)
  • Fan motor issues – Indoor or outdoor fan blocked, faulty, or malfunctioning (E1, H6/E5, F9)
  • Compressor problems – Phase failure, overheating, or loss of synchronization (F1, F2, F4)
  • Communication failures – Damaged wiring or loose connectors between indoor and outdoor units (E6, E8)
  • PCB or memory faults – Internal EEPROM errors in indoor or outdoor unit control boards (EE, E0)
  • Frost or overheat protection – Automatic safety cutoffs triggered by low airflow, dirty filters, or blocked coils (dF, HF, HP)
  • Voltage fluctuations – Unstable power supply affecting sensors, PCB, or compressor operation
  • Dust and poor maintenance – Dirty filters or coils restricting airflow and triggering protection codes
  • IPM module faults – Internal power module issues in the outdoor unit (F3)
  • Normal operating conditions – Some sounds, mist, or brief delays are not errors and need no action

Inverter Godrej Split AC Error Codes

Error Codes & MeaningQuick Solutions
EE – Indoor machine EE faultRestart the unit. If error continues, indoor PCB needs professional inspection.
E1 – Indoor fan faultCheck nothing blocks the indoor fan. Restart AC. Call technician if it repeats.
E2 – Indoor fan zero-crossing detection abnormalRestart AC. If code stays, indoor PCB needs technician check.
E3 – Indoor coil fault and sensor faultRestart unit. Clean the filter and coil. Persistent error needs technician visit.
E4 – Indoor ambient temperature sensor faultPower cycle the AC. If error returns, sensor replacement is required.
E0 – Outdoor EE faultRestart the unit. If fault persists, outdoor PCB memory needs technician check.
E6 – Indoor and outdoor communication faultCheck wiring between indoor and outdoor units. Restart AC. Call technician if unresolved.
E8 – Outdoor communication faultCheck wiring connections at the outdoor unit. Call technician if error persists.
F1 – Compressor starting abnormal (phase failure, reverse)Check power supply and voltage. Call technician for compressor or wiring check.
F2 – Compressor out-of-step faultRestart AC after a few minutes. Persistent fault needs technician diagnosis.
F3 – IPM module faultTurn off AC and call a technician. This is an internal outdoor unit fault.
F4 – Compressor shell roof fault/protectionTurn off AC, let it cool for 30 minutes. Check outdoor unit ventilation before restart.
F5 – Discharge temperature sensor faultRestart unit. If error repeats, sensor needs technician replacement.
F6 – Suction temperature sensor faultRestart AC. Persistent error needs professional sensor check.
F7 – Outdoor coil temperature sensor faultCheck outdoor unit for dust or blockage. Call technician if error stays.
F8 – Outdoor ambient temperature sensor faultRestart the unit. If unresolved, sensor replacement is needed.
F9 – Outdoor DC fan faultCheck outdoor fan for obstruction. Call technician if fan does not spin freely.

Fixed Speed Godrej AC Error Codes

Error Codes & MeaningQuick Solutions
H6/E5 – IDU fan motor protectionTurn off AC, check nothing blocks the indoor fan, restart. Call technician if it repeats.
dF – Frost protectionNormal auto-defrost. If it triggers often, check filter, airflow, or refrigerant level.
E1 – Room sensor errorTurn off AC, wait 10 minutes, restart. If it repeats, call a technician to check the sensor.
E2 – Evaporator sensor errorRestart the unit. Clean the filter and coil. If error stays, sensor needs replacement.
U8* – Zero cross detectionRestart AC. If code stays, indoor PCB needs technician check.
E3* – ODU coil sensor error (in heat mode)Restart AC. If fault continues in heat mode, call technician for sensor check.
HF* – ODU frost protection (in heat mode)Normal defrost cycle. Frequent triggering needs technician inspection.
HP* – IDU coil over heat protection (in heat mode)Turn off AC, let it cool, check airflow around indoor unit. Call technician if it repeats.

* For selected models only






    *We do not claim copyright over the logos and brand names used on our website; they are used for illustration purposes only. See disclaimer.

    Godrej split and window ACs display error codes on the indoor unit when a sensor, fan, or compressor fault is detected, helping users spot problems early. 

    These differ from protection codes like dF (frost protection) or H6 (fan motor protection), which are safety cutoffs the AC triggers on its own to prevent damage, not actual faults. 

    This guide covers both inverter and fixed speed Godrej Split and Window AC models, based strictly on official Godrej user manuals, so Indian users can quickly identify the issue before deciding whether a simple restart helps or a technician visit is needed.

    trusted source google

    Godrej Fixed Speed (Non-Inverter) AC Error Code Explanation With Solutions

    godrej split ac

    dF – Frost Protection

    What Causes This Error: The AC’s frost protection feature activates when the evaporator coil gets too cold, usually due to low airflow, a dirty filter, or low refrigerant.

    How to Fix The Error: Turn off the AC, clean or replace the filter, and check that airflow is not blocked. If frost keeps forming, call a technician to check the refrigerant level.

    E1 – Room Sensor Error

    What Causes This Error: This appears when the room temperature sensor is short-circuited or has an open connection, so the AC cannot read the room temperature correctly.

    How to Fix The Error: Restart the AC after 10 minutes. If the error returns, a technician needs to inspect or replace the room sensor.

    E2 – Evaporator Sensor Error

    What Causes This Error: This occurs when the evaporator coil sensor is short-circuited or open, preventing accurate coil temperature readings.

    How to Fix The Error: Restart the unit and clean the filter and coil. If the error persists, the sensor likely needs replacement by a technician.

    E3 – Condenser (Outdoor Coil) Sensor Error (Heat mode only)

    What Causes This Error: This happens when the condenser coil sensor is short-circuited or open, mainly noticed during heat mode operation.

    How to Fix The Error: Restart the AC and check the outdoor unit is not blocked or dusty. Persistent errors need a technician visit for sensor replacement.

    E5 / H6 – Indoor Fan Motor Protection

    What Causes This Error: This triggers when the indoor fan motor has a fault, causing the compressor and fan to shut off immediately as a safety measure.

    How to Fix The Error: Turn off the AC, check nothing is blocking the indoor fan, and restart. If the fan does not spin freely, call a technician to check the motor.

    U8 – Zero Cross Detection (Selected models only)

    What Causes This Error: This code appears when the AC’s zero-crossing detection circuit, used for fan speed control, malfunctions.

    How to Fix The Error: Restart the AC. If the code continues to appear, the indoor PCB needs professional inspection.

    HF – Outdoor Unit Frost Protection (Heat mode only, selected models only)

    What Causes This Error: This is a normal protection response when the outdoor coil frosts up during heat mode operation.

    How to Fix The Error: This is usually part of the normal defrost cycle. If it triggers too often, have a technician inspect the outdoor unit.

    HP – Indoor Coil Overheat Protection (Heat mode only, selected models only)

    What Causes This Error: This activates when the indoor coil overheats during heat mode, often due to restricted airflow.

    How to Fix The Error: Turn off the AC, let it cool, and check for blocked airflow around the indoor unit. Call a technician if the issue repeats.

    Godrej Inverter AC Error Code Explanation With Solutions

    godrej split ac

    Indoor Unit

    EE – Indoor Machine EE Fault

    What Causes This Error: Indicates an internal memory (EEPROM) fault in the indoor unit’s PCB.

    How to Fix The Error: Restart the unit. If the error continues, the indoor PCB needs professional inspection.

    E1 – Indoor Fan Fault

    What Causes This Error: Occurs when the indoor fan motor is obstructed or malfunctioning.

    How to Fix The Error: Check nothing blocks the indoor fan and restart the AC. Call a technician if it repeats.

    E2 – Indoor Fan Zero-Crossing Detection Abnormal

    What Causes This Error: Happens when the fan speed detection circuit fails to read signals correctly.

    How to Fix The Error: Restart the AC. If the code stays, the indoor PCB needs a technician check.

    E3 – Indoor Coil Fault / Indoor Coil Sensor Fault

    What Causes This Error: Triggered when the indoor coil sensor is faulty or the coil itself has an issue.

    How to Fix The Error: Restart the unit and clean the filter and coil. Persistent errors need a technician visit.

    E4 – Indoor Ambient Temperature Sensor Fault

    What Causes This Error: Appears when the room ambient temperature sensor is short or open.

    How to Fix The Error: Power cycle the AC. If the error returns, the sensor needs replacement.

    E6 – Indoor & Outdoor Unit Communication Fault

    What Causes This Error: Caused by a broken signal, damaged wiring, or connector issue between indoor and outdoor units.

    How to Fix The Error: Check the wiring between both units and restart the AC. Call a technician if unresolved.

    Outdoor Unit

    E0 – Outdoor EE Fault

    What Causes This Error: Indicates an internal memory (EEPROM) fault in the outdoor unit’s PCB.

    How to Fix The Error: Restart the unit. If the fault persists, the outdoor PCB needs a technician check.

    E8 – Outdoor Communication Fault

    What Causes This Error: Occurs due to a break or fault in the communication line at the outdoor unit.

    How to Fix The Error: Check wiring connections at the outdoor unit. Call a technician if the error persists.

    F1 – Compressor Starting Abnormal (Phase Failure / Reverse Phase)

    What Causes This Error: Happens when the compressor fails to start due to phase failure or reversed wiring.

    How to Fix The Error: Check the power supply and voltage. A technician should check the compressor wiring.

    F2 – Compressor Out-of-Step Fault

    What Causes This Error: Occurs when the compressor motor loses synchronization during operation.

    How to Fix The Error: Restart the AC after a few minutes. Persistent faults need technician diagnosis.

    F3 – IPM Module Fault

    What Causes This Error: Indicates a fault in the outdoor unit’s Intelligent Power Module, which controls the compressor.

    How to Fix The Error: Turn off the AC and call a technician, as this is an internal outdoor unit component fault.

    F4 – Compressor Shell Temperature Protection / Shell Roof Fault

    What Causes This Error: Triggers when the compressor shell overheats beyond a safe limit.

    How to Fix The Error: Turn off the AC and let it cool for 30 minutes. Check outdoor unit ventilation before restarting.

    F5 – Discharge Temperature Sensor Fault

    What Causes This Error: Occurs when the sensor monitoring the compressor’s discharge temperature fails.

    How to Fix The Error: Restart the unit. If the error repeats, the sensor needs technician replacement.

    F6 – Suction Temperature Sensor Fault

    What Causes This Error: Happens when the sensor monitoring the suction line temperature is short or open.

    How to Fix The Error: Restart the AC. Persistent errors need professional sensor inspection.

    F7 – Outdoor Coil Temperature Sensor Fault

    What Causes This Error: Triggered when the outdoor coil temperature sensor malfunctions.

    How to Fix The Error: Check the outdoor unit for dust or blockage. Call a technician if the error stays.

    F8 – Outdoor Ambient Temperature Sensor Fault

    What Causes This Error: Occurs when the sensor reading outdoor ambient temperature is faulty.

    How to Fix The Error: Restart the unit. If unresolved, the sensor needs replacement.

    F9 – Outdoor DC Fan Fault

    What Causes This Error: Happens when the outdoor DC fan motor fails to run correctly.

    How to Fix The Error: Check the outdoor fan for obstructions. Call a technician if the fan does not spin freely.

    Urban Service Plaza is the best Godrej Service Centre in Kolkata for expired warranty products. Hire our technicians for same day appliance repair at your doorstep. 

    Troubleshoot for Most Common Godrej AC Problems

    ac compressor 2

    AC does not operate immediately after being restarted 

    This happens because the compressor has a built-in overload protection delay. It is completely normal, and the AC will restart on its own after about 3 minutes.

    Unusual smell coming from the indoor unit 

    The AC itself does not produce odors. The smell usually comes from dust, smoke, furniture, or other odors that have accumulated inside the unit. Clean the air filter, and if the odor persists, have the indoor unit professionally cleaned by an authorized service center.

    Water-flow or gurgling sound during operation 

    This sound is caused by refrigerant flowing inside the system as the compressor starts, stops, or operates. It is a normal operating condition and does not need any action.

    Mist coming out of the air outlet in Cool mode 

    This can happen when room temperature and humidity are very high, causing rapid cooling of room air to condense into mist. Continue operating the AC, and the mist will disappear as room temperature and humidity decrease.

    Creaking or cracking noise when the AC starts or stops 

    This noise is caused by plastic components inside the unit expanding and contracting due to temperature changes. It is normal and does not indicate a fault.

    The air conditioner does not run 

    Check whether the power supply has been switched off, the plug is loose, or the circuit breaker or fuse has tripped. Also verify the supply voltage is not too high or too low, and confirm the TIMER function has not been set incorrectly.

    Cooling or heating performance is poor 

    Check that the temperature setting is appropriate, the fan speed is not too low, and the indoor and outdoor vents are not blocked. Dirty filters, open doors or windows, and heat sources inside the room can also reduce performance.

    Wireless remote control does not work 

    Unplug the AC, wait briefly, and reconnect the power, as electrical interference can temporarily affect the remote. Also check that the remote is within range, its batteries are not weak, and it is not physically damaged.

    Water leaking from the indoor unit 

    This can happen due to high indoor humidity causing condensation, condensate water overflow, or a loose or disconnected drain pipe connection. Check the drain pipe connection first, and contact a technician if the leak continues.

    Water leaking from the outdoor unit 

    This is usually caused by condensation on refrigerant pipes during cooling, melted frost during automatic defrost, or condensed water from the outdoor heat exchanger during heating. These conditions are generally normal and do not need any action.

    Noise coming from the indoor unit 

    Clicking sounds may come from the fan or compressor relay switching on and off, while refrigerant flow and fan noise can occur during defrost operation. These are normal operating sounds and do not indicate a fault.

    Indoor unit does not blow air (Heat & Cool models only) 

    In HEAT mode, the indoor fan stays off until the heat exchanger warms up, usually within about 2 minutes. During automatic defrost, the fan may stop for 3 to 12 minutes, and it may pause briefly in Dry mode to prevent condensed water from evaporating back into the room.

    Moisture on the air outlet vent 

    When the AC runs for a long time in high humidity, moisture may condense on the air outlet grille and drip. This is normal and does not require any action.

    When to Call Godrej Service Centre for Technician Visit?

    • There is a harsh or abnormal sound during operation. An unusual sound during operation often signals a fan, motor, or compressor problem inside the unit. This is not something to fix on your own, so a technician should inspect it right away.
    • A burning or unusual odor is emitted from the unit. A burning smell usually means overheating wiring, a damaged PCB, or an electrical fault inside the AC. This is a serious warning sign, and the unit should be turned off immediately and checked by a professional.
    • Water is leaking inside the room continuously. Continuous water leakage can point to a blocked drain, damaged indoor unit, or an installation issue. Ignoring it can lead to fire risk or damage to the unit, so a technician visit is needed.
    • The air switch or circuit breaker trips frequently. Repeated tripping usually indicates an electrical fault, overload, or a wiring problem inside the AC. This should be checked by a trained technician instead of resetting the breaker repeatedly.
    • Water or any foreign object accidentally enters the indoor unit. If water or any foreign substance gets inside the appliance, the power supply should be cut off immediately and a service centre contacted. Continuing to use the AC in this condition can lead to electric shock or fire.
    • The power cord or plug becomes abnormally hot. An abnormally hot power cord or plug is a sign of loose connections or electrical damage. This is a fire hazard, and a technician should inspect and replace the cord if required.

    Godrej AC error codes help you spot problems early, before they turn into bigger repairs. Start with simple steps like a power reset, filter cleaning, and airflow checks.