Daikin AC Error Codes & Troubleshooting Guide

daikin ac error codes

Daikin split and window ACs use a self-diagnosis system to alert users about faults. When something goes wrong, the unit displays an error code through the remote control or an LED blink pattern on the indoor unit. Some codes point to genuine component faults, like a sensor or PCB issue, while others are protection codes. 

These appear when the AC shuts down on purpose, such as during high pressure or overload, to prevent damage. This guide covers both split and window Daikin AC models and is based on official Daikin user manuals, made simple for Indian homeowners facing sudden AC breakdowns.

trusted source google

Quick Find Your Daikin AC Error Codes

Error Code & MeaningQuick Solution
00 – Normal operationNo action needed
A1 – Indoor PCB faultPower cycle unit; call technician if code repeats
A3 – Drain pump/level control abnormalCheck drain pipe for blockage; clean drain line
A5 – Antifreeze / heat exchanger overheatClean air filter; check refrigerant level
A6 – Indoor fan motor faultCheck fan for obstruction; call technician
AH – Electrical air cleaner faultClean/reset air cleaner unit
C4 – Indoor heat exchanger (1) sensor short/openCall technician to replace sensor
C5 – Indoor heat exchanger (2) sensor short/openCall technician to replace sensor
C7 – Louver limit switch errorCheck swing flap for obstruction
C9 – Indoor room sensor short/openCall technician to replace sensor
CC – Humidity sensor faultCall technician
E1 – Outdoor/circuit board faultPower cycle; call technician if persists
E3 – High pressure protectionClean filters and outdoor coil; check airflow
E4 – Low pressure protectionCheck for refrigerant leak; call technician
E5 – Compressor motor lock/overloadTurn off, let rest, restart; call technician
E6 – Compressor start-up faultCall technician
E7 – Outdoor DC fan motor lockCheck for debris blocking outdoor fan
E8 – AC input overcurrentCheck power supply; call technician
E9 – EXV (expansion valve) errorCall technician
EA – 4-way valve errorCall technician
F3 – Discharge pipe overheatClean filters/coils; check refrigerant
F6 – High pressure/heat exchanger overheatClean outdoor unit; ensure airflow clearance
H0 – Compressor sensor system errorCall technician
H3 – High pressure switch errorCheck outdoor coil for blockage
H6 – Position/feedback detection errorCall technician
H7 – Fan motor overload/signal faultCheck outdoor fan for obstruction
H8 – AC current sensor errorCall technician
H9 – Outdoor air thermistor short/openCall technician to replace sensor
J1 – Pressure sensor errorCall technician
J3 – Discharge pipe thermistor short/open/misplacedCall technician
J5 – Suction pipe thermistor short/openCall technician
J6 – Outdoor heat exchanger thermistor short/openCall technician
J7 – Subcooling heat exchanger thermistor short/openCall technician
J8 – Liquid pipe thermistor short/openCall technician
J9 – Gas pipe thermistor short/openCall technician
L3 – Outdoor control box overheatClean outdoor unit; ensure ventilation
L4 – Heat sink overheatClean outdoor unit; check ventilation space
L5 – IPM/IGBT errorCall technician
L8 – Inverter compressor overcurrentCall technician
L9 – Compressor overcurrent preventionTurn off and let rest; call technician if repeats
LC – Communication error (control-inverter PCB)Power cycle; call technician if persists
P1 – Open phase/voltage unbalanceCheck power supply and wiring
P4 – Heat sink thermistor short/openCall technician
PJ – Capacity setting errorCall technician
U0 – Insufficient refrigerant gasCall technician for leak check and refill
U2 – DC voltage out of rangeCheck power supply stability
U3 – Transmission errorPower cycle; check wiring
U4 – Communication error (indoor-outdoor)Power cycle; inspect connecting wires
U7 – Communication error (control-IPM PCB)Call technician
UA – Installation/unit combination errorCall technician to verify installation
UF – Piping/wiring mismatch or insufficient gasCall technician
UH – Antifreeze (other rooms, multi-system)Check other indoor units on system






    *We do not claim copyright over the logos and brand names used on our website; they are used for illustration purposes only. See disclaimer.

    TL;DR:

    • Daikin ACs display error codes through the remote or LED blinks to flag specific faults.
    • Common causes include sensor faults, PCB issues, refrigerant leaks, voltage problems, and communication failures between indoor and outdoor units.
    • A quick reference table helps you match error codes to their meaning and possible fix.
    • Codes A1 to CC point to indoor unit issues like PCB, drain pump, sensors, and fan motor faults.
    • Codes E1 to H9 relate to outdoor unit problems such as compressor, pressure, and fan motor faults.
    • Codes J1 to LC cover thermistor faults and inverter or control board overheating.
    • Codes P1 to UH indicate voltage issues, installation errors, and refrigerant or communication faults.
    • Common Daikin AC problems include poor cooling, water leakage, remote issues, and airflow trouble.
    • Start with basic fixes like a power reset, filter cleaning, and checking airflow before calling for service.
    • Call Urban Service Plaza for a technician visit if the error repeats, the AC malfunctions, or you notice a burning smell, hot power cord, or water leakage.

    Daikin AC Error Code Explanation With Possible Solutions

    daikin ac

    A1 – Indoor PCB fault

    What Causes This Error:

    • Moisture entering the PCB during humid weather or servicing
    • Voltage surges, dust buildup, or corrosion damaging circuit tracks
    • Loose or burnt wiring connections

    How to Fix The Error:

    • Turn off the AC and inspect for burnt marks or moisture near the PCB
    • Clean dust gently with a soft brush
    • If damage is visible, call a technician to repair or replace the PCB

    A3 – Drain pump/level control abnormal

    What Causes This Error:

    • Clogged condensate drain pipe blocked by dust, algae, or debris
    • Faulty or worn-out condensate pump
    • Incorrect drain pipe slope after installation

    How to Fix The Error:

    • Check and clean the drain pipe and drain tray
    • Flush the line with a vacuum or hose to clear blockage
    • If pooling continues, ask a technician to inspect or replace the pump

    A5 – Antifreeze / heat exchanger overheat

    What Causes This Error:

    • Dirty air filter or coil restricting airflow
    • Low refrigerant causing the coil to overcool and freeze
    • Faulty coil sensor failing to stop the compressor in time

    How to Fix The Error:

    • Turn off the AC and let the ice melt fully
    • Clean the filter and evaporator coil
    • Call a technician to check refrigerant level and sensor function

    A6 – Indoor fan motor fault

    What Causes This Error:

    • Weak or faulty fan motor capacitor
    • Jammed or worn-out bearings inside the blower
    • Burnt or weak motor winding

    How to Fix The Error:

    • Check if the fan spins freely by hand with power off
    • Test and replace the capacitor if weak
    • Call a technician to replace the motor if winding is damaged

    AH – Electrical air cleaner fault

    What Causes This Error:

    • Fault in the electrical air-purifying filter system
    • Dust accumulation short-circuiting the cleaner unit
    • Wiring or connector issue in the air cleaner module

    How to Fix The Error:

    • Clean the electrical air cleaner filter
    • Check its wiring connection for looseness
    • Contact a technician if the fault continues after cleaning

    C4 – Indoor heat exchanger (1) sensor short/open

    What Causes This Error:

    • Sensor wire damaged, loose, or corroded
    • Sensor exposed to excess moisture
    • Natural wear of the thermistor over time

    How to Fix The Error:

    • Do not attempt DIY sensor replacement, as calibration is needed
    • Call a technician to test sensor resistance
    • Replace the faulty sensor with a genuine part

    C5 – Indoor heat exchanger (2) sensor short/open

    What Causes This Error:

    • Same causes as C4, affecting the second heat exchanger sensor
    • Common in dual-sensor coil designs for precise temperature control
    • Sensor aging or moisture damage

    How to Fix The Error:

    • Call a technician to check both coil sensors together
    • Replace the faulty sensor using an OEM part
    • Ensure correct sensor placement after replacement

    C7 – Louver limit switch error

    What Causes This Error:

    • Swing flap obstructed by dust or foreign objects
    • Broken flap lock, hinge, or plastic coupling
    • Faulty swing motor or loose motor connector

    How to Fix The Error:

    • Power cycle the AC and check if the flap resets
    • Clean the flap area of dust and obstructions
    • Call a technician if the motor or coupling needs replacement

    Urban Service Plaza is the best AC Service Centre in Kolkata for expired warranty products. Hire our technicians for same day appliance repair at your doorstep. 

    C9 – Indoor room sensor short/open

    What Causes This Error:

    • Damaged or loose room temperature sensor wiring
    • Sensor jack not properly seated
    • Moisture or aging affecting sensor accuracy

    How to Fix The Error:

    • Check the sensor jack connection carefully
    • Clean or tighten the connector if loose
    • Call a technician to replace the sensor if the fault persists

    CC – Humidity sensor fault

    What Causes This Error:

    • Malfunction in the humidity sensing circuit
    • Dust or moisture affecting sensor readings
    • Wiring fault between sensor and PCB

    How to Fix The Error:

    • Power cycle the unit to reset the sensor reading
    • Inspect sensor wiring for visible damage
    • Call a technician to test and replace the humidity sensor if needed

    E1 – Outdoor/circuit board fault

    What Causes This Error:

    • Voltage surges or moisture damaging the outdoor PCB
    • Loose wiring or burnt tracks on the circuit board
    • Aging PCB components after years of use

    How to Fix The Error:

    • Turn the AC off and on again to reset the board
    • Check for burnt smell or visible damage on the outdoor PCB
    • Call a technician to repair or replace the circuit board if the fault repeats

    E3 – High pressure protection

    What Causes This Error:

    • Dirty condenser coil restricting heat release
    • Blocked airflow around the outdoor unit
    • Refrigerant overcharging raising system pressure

    How to Fix The Error:

    • Clean the outdoor condenser coil and remove nearby obstructions
    • Ensure enough space around the outdoor unit for airflow
    • Call a technician to check refrigerant charge if the code repeats

    E4 – Low pressure protection

    What Causes This Error:

    • Refrigerant leak lowering system pressure
    • Blocked capillary tube or filter drier
    • Faulty pressure sensor giving incorrect readings

    How to Fix The Error:

    • Do not attempt to add refrigerant yourself
    • Call a technician to detect and repair the leak
    • Ask the technician to recharge refrigerant to the correct pressure

    E5 – Compressor motor lock/overload

    What Causes This Error:

    • Compressor overheating due to dirty condenser or high ambient temperature
    • Weak or faulty capacitor putting extra load on the compressor
    • Low lubrication oil inside the compressor

    How to Fix The Error:

    • Turn off the AC and let the compressor cool down
    • Test and replace the capacitor if weak
    • Call a technician if the compressor keeps locking after cooling

    E6 – Compressor start-up fault

    What Causes This Error:

    • Faulty start capacitor unable to give the compressor enough starting torque
    • Low voltage supply preventing normal startup
    • Internal compressor winding damage

    How to Fix The Error:

    • Check the incoming voltage supply and use a stabilizer if needed
    • Test the compressor capacitor with a multimeter
    • Call a technician to inspect the compressor windings if the fault continues

    E7 – Outdoor DC fan motor lock

    What Causes This Error:

    • Debris, dust, or obstruction blocking the fan blades
    • Worn-out or seized fan motor bearings
    • Faulty fan motor or capacitor

    How to Fix The Error:

    • Turn off power and check if the fan spins freely by hand
    • Clear any obstruction around the outdoor fan
    • Call a technician to replace the motor or capacitor if it stays locked

    E8 – AC input overcurrent

    What Causes This Error:

    • Voltage fluctuation or unstable power supply
    • Compressor drawing excess current due to internal fault
    • Short circuit in wiring

    How to Fix The Error:

    • Check the power supply voltage and use a stabilizer
    • Inspect wiring for short circuits or loose connections
    • Call a technician to measure compressor current draw

    E9 – EXV (expansion valve) error

    What Causes This Error:

    • Faulty electronic expansion valve coil or motor
    • Blocked or stuck valve restricting refrigerant flow
    • Wiring or connector fault between EXV and PCB

    How to Fix The Error:

    • Power cycle the unit to reset the valve position
    • Call a technician to test the EXV coil resistance
    • Replace the valve or repair wiring as advised by the technician

    EA – 4-way valve error

    What Causes This Error:

    • Faulty 4-way valve coil affecting cooling/heating mode switching
    • Valve stuck due to dirt or wear
    • Wiring fault between the valve and PCB

    How to Fix The Error:

    • Power cycle the AC and try switching modes again
    • Call a technician to test the 4-way valve coil
    • Replace the valve if it fails to switch properly

    F3 – Discharge pipe overheat

    What Causes This Error:

    • Dirty filters or coils reducing airflow and heat exchange
    • Low refrigerant level increasing compressor workload
    • Blocked capillary tube raising discharge temperature

    How to Fix The Error:

    • Clean air filters and both indoor and outdoor coils
    • Call a technician to check refrigerant level and pressure
    • Ask for capillary tube inspection if overheating continues

    F6 – High pressure/heat exchanger overheat

    What Causes This Error:

    • Blocked outdoor coil reducing heat rejection
    • Poor ventilation around the outdoor unit
    • Refrigerant overcharge raising system pressure

    How to Fix The Error:

    • Clean the outdoor unit and ensure clear airflow space
    • Avoid installing the outdoor unit in a tightly enclosed area
    • Call a technician to check and correct refrigerant charge

    H0 – Compressor sensor system error

    What Causes This Error:

    • Faulty sensor monitoring compressor operation
    • Damaged sensor wiring or connector
    • PCB fault misreading sensor signal

    How to Fix The Error:

    • Power cycle the unit to reset the sensor reading
    • Call a technician to test the compressor sensor
    • Replace the sensor or repair PCB connection as needed

    H3 – High pressure switch error

    What Causes This Error:

    • Dirty condenser coil raising system pressure
    • Faulty high-pressure switch failing to reset
    • Blocked airflow around the outdoor unit

    How to Fix The Error:

    • Clean the condenser coil and clear obstructions
    • Check for adequate space around the outdoor unit
    • Call a technician to test and replace the pressure switch if needed

    H6 – Position/feedback detection error

    What Causes This Error:

    • Faulty position sensor on the compressor
    • Wiring fault between sensor and PCB
    • PCB failing to detect correct feedback signal

    How to Fix The Error:

    • Power cycle the AC to reset the detection system
    • Call a technician to check sensor wiring and connections
    • Replace the faulty sensor or PCB as advised

    H7 – Fan motor overload/signal fault

    What Causes This Error:

    • Fan motor drawing excess current due to mechanical strain
    • Obstruction preventing free fan rotation
    • Faulty signal wire between motor and PCB

    How to Fix The Error:

    • Turn off power and check if the fan rotates freely by hand
    • Clear obstructions and dust from the fan area
    • Call a technician to test motor windings and signal wiring

    H8 – AC current sensor error

    What Causes This Error:

    • Faulty current sensor circuit on the PCB
    • Voltage fluctuation affecting sensor readings
    • Damaged wiring near the current sensor

    How to Fix The Error:

    • Check power supply stability and use a stabilizer if needed
    • Power cycle the unit to reset the sensor
    • Call a technician to test or replace the current sensor

    H9 – Outdoor air thermistor short/open

    What Causes This Error:

    • Damaged or corroded outdoor air temperature sensor
    • Loose or disconnected sensor wiring
    • Sensor exposed to moisture or extreme weather

    How to Fix The Error:

    • Call a technician to test the thermistor resistance value
    • Check the sensor wiring for looseness or damage
    • Replace the faulty thermistor with a genuine part

    J1 – Pressure sensor error

    What Causes This Error:

    • Faulty refrigerant pressure sensor giving incorrect readings
    • Loose or damaged sensor wiring connection
    • Sensor exposed to moisture or physical damage

    How to Fix The Error:

    • Power cycle the AC to reset the sensor reading
    • Call a technician to test the pressure sensor connection
    • Replace the faulty sensor with a genuine part if the fault continues

    J3 – Discharge pipe thermistor short/open/misplaced

    What Causes This Error:

    • Damaged or corroded thermistor on the compressor discharge pipe
    • Loose sensor wiring or connector
    • Sensor incorrectly positioned during installation or servicing

    How to Fix The Error:

    • Call a technician to check sensor placement on the discharge pipe
    • Test the thermistor resistance value with a multimeter
    • Replace or reposition the sensor as needed

    J5 – Suction pipe thermistor short/open

    What Causes This Error:

    • Faulty thermistor monitoring suction line temperature
    • Damaged or loose sensor wiring
    • Corrosion from moisture exposure over time

    How to Fix The Error:

    • Call a technician to test the suction pipe sensor
    • Check wiring connections for damage
    • Replace the thermistor if resistance readings are abnormal

    J6 – Outdoor heat exchanger thermistor short/open

    What Causes This Error:

    • Damaged sensor on the outdoor condenser coil
    • Loose or corroded wiring connection
    • Sensor affected by weather exposure or dust buildup

    How to Fix The Error:

    • Call a technician to inspect and test the coil sensor
    • Clean surrounding dust and check wiring
    • Replace the sensor if it fails the resistance test

    J7 – Subcooling heat exchanger thermistor short/open

    What Causes This Error:

    • Faulty subcooling sensor common in multi-split or larger systems
    • Loose wiring or connector fault
    • Sensor aging or moisture damage

    How to Fix The Error:

    • Call a technician to test the subcooling sensor
    • Inspect wiring for looseness or corrosion
    • Replace the sensor with a genuine part if needed

    J8 – Liquid pipe thermistor short/open

    What Causes This Error:

    • Damaged sensor on the liquid refrigerant line
    • Dirty or blocked condenser affecting sensor readings indirectly
    • Loose sensor wiring connection

    How to Fix The Error:

    • Clean the condenser coil to rule out airflow issues
    • Call a technician to test the liquid line sensor
    • Replace the faulty thermistor if confirmed

    J9 – Gas pipe thermistor short/open

    What Causes This Error:

    • Faulty thermistor on the gas refrigerant line
    • Loose or damaged wiring connector
    • Sensor wear from long-term outdoor exposure

    How to Fix The Error:

    • Call a technician to test the gas pipe sensor
    • Check and secure wiring connections
    • Replace the sensor if resistance values are abnormal

    L3 – Outdoor control box overheat

    What Causes This Error:

    • Poor ventilation around the outdoor control box
    • Dust accumulation restricting heat dissipation
    • Outdoor unit installed in direct sunlight or an enclosed space

    How to Fix The Error:

    • Clean the outdoor unit and control box area
    • Ensure proper shade and airflow around the outdoor unit
    • Call a technician if overheating continues after cleaning

    L4 – Heat sink overheat

    What Causes This Error:

    • Dry or degraded thermal paste on the inverter heat sink
    • Loose heat sink mounting reducing heat transfer
    • Blocked airflow inside the outdoor unit

    How to Fix The Error:

    • Call a technician to check and reapply thermal paste
    • Ensure the heat sink is mounted tightly
    • Clean the outdoor unit to improve internal airflow

    L5 – IPM/IGBT error

    What Causes This Error:

    • IPM (Intelligent Power Module) overheating or internal damage
    • Dry thermal paste between the IPM and heat sink
    • Voltage fluctuation damaging the module

    How to Fix The Error:

    • Call a technician to inspect the IPM module and thermal paste
    • Use a stabilizer to protect against voltage fluctuation
    • Replace the IPM module if it is damaged

    L8 – Inverter compressor overcurrent

    What Causes This Error:

    • Compressor drawing excess current due to mechanical strain
    • Voltage fluctuation affecting inverter output
    • Refrigerant overcharge increasing compressor load

    How to Fix The Error:

    • Check power supply voltage and use a stabilizer if needed
    • Call a technician to measure compressor current draw
    • Ask for refrigerant charge verification if overcurrent continues

    L9 – Compressor overcurrent prevention

    What Causes This Error:

    • Compressor protection triggered by high current demand
    • Dirty condenser increasing compressor workload
    • Low refrigerant causing the compressor to work harder

    How to Fix The Error:

    • Clean the condenser coil and ensure good airflow
    • Turn off the AC and let the compressor cool before restarting
    • Call a technician to check refrigerant level and compressor health

    LC – Communication error (control-inverter PCB)

    What Causes This Error:

    • Faulty connection between the outdoor control PCB and inverter PCB
    • Damaged internal wiring or connector
    • PCB component failure due to voltage surge or moisture

    How to Fix The Error:

    • Power cycle the unit to attempt a reset
    • Call a technician to test communication voltage between the boards
    • Repair or replace the faulty PCB as advised

    P1 – Open phase/voltage unbalance

    What Causes This Error:

    • One power phase missing or disconnected in three-phase outdoor units
    • Voltage imbalance between phases due to grid fluctuation
    • Loose wiring at the main power terminal

    How to Fix The Error:

    • Check the main power supply and wiring connections
    • Ensure all phases are properly connected and balanced
    • Call a technician if the fault continues after checking wiring

    P4 – Heat sink thermistor short/open

    What Causes This Error:

    • Damaged or corroded sensor monitoring the inverter heat sink
    • Loose sensor wiring or connector
    • Sensor aging from repeated heat exposure

    How to Fix The Error:

    • Call a technician to test the heat sink thermistor
    • Check sensor wiring for damage or looseness
    • Replace the sensor with a genuine part if faulty

    PJ – Capacity setting error

    What Causes This Error:

    • Mismatch between indoor and outdoor unit capacity settings
    • Incorrect DIP switch or PCB configuration during installation or servicing
    • Using an indoor and outdoor unit combination not meant for each other

    How to Fix The Error:

    • Call a technician to verify indoor-outdoor unit compatibility
    • Check and correct the capacity setting on the PCB
    • Ensure genuine, matched Daikin components are used

    U0 – Insufficient refrigerant gas

    What Causes This Error:

    • Refrigerant leak at flare joints, brazed connections, or damaged tubing
    • Undercharged refrigerant during a previous service
    • Long-term gradual gas loss from small leaks

    How to Fix The Error:

    • Do not attempt a DIY gas refill
    • Call a technician to detect and repair the leak first
    • Ask the technician to vacuum the system and recharge with the correct refrigerant type and quantity

    U2 – DC voltage out of range

    What Causes This Error:

    • Unstable main power supply or voltage fluctuation
    • Faulty inverter PCB component
    • Capacitor issue on the inverter circuit

    How to Fix The Error:

    • Check incoming voltage and use a stabilizer if needed
    • Power cycle the unit to see if the fault clears
    • Call a technician to inspect the inverter PCB if the error repeats

    U3 – Transmission error

    What Causes This Error:

    • Faulty or loose connection wire between indoor and outdoor units
    • Communication circuit fault on either PCB
    • Interference or wiring damage along the connecting cable

    How to Fix The Error:

    • Power cycle the AC to attempt a reset
    • Check the connecting wire between indoor and outdoor units for damage
    • Call a technician to test communication voltage on both PCBs

    U4 – Communication error (indoor-outdoor)

    What Causes This Error:

    • Loose, cut, or damaged communication wire between indoor and outdoor units
    • Blown fuse or damaged component on either PCB
    • Moisture or voltage surge affecting the communication circuit

    How to Fix The Error:

    • Turn off the AC and inspect the connecting cable for visible damage
    • Power cycle the unit to check if communication resumes
    • Call a technician to test communication voltage and repair or replace the faulty PCB

    U7 – Communication error (control-IPM PCB)

    What Causes This Error:

    • Faulty connection between the outdoor control PCB and IPM PCB
    • Damaged internal wiring or connector
    • IPM component failure affecting signal transmission

    How to Fix The Error:

    • Power cycle the unit to attempt a reset
    • Call a technician to test the connection between the two boards
    • Repair or replace the faulty PCB or IPM as advised

    UA – Installation/unit combination error

    What Causes This Error:

    • Incompatible indoor and outdoor unit combination
    • Incorrect DIP switch settings during installation
    • Wiring or capacity mismatch between units

    How to Fix The Error:

    • Call a technician to confirm the indoor and outdoor units are a matched pair
    • Verify correct installation settings on the PCB
    • Reinstall or reconfigure the system as per Daikin’s specifications

    UF – Piping/wiring mismatch or insufficient gas

    What Causes This Error:

    • Incorrect wiring connections between indoor and outdoor units
    • Excess or improperly routed copper piping during installation
    • Insufficient refrigerant charge after installation

    How to Fix The Error:

    • Call a technician to verify wiring matches the correct terminal sequence
    • Check piping length and routing against manufacturer specification
    • Ask the technician to correct the refrigerant charge if it is insufficient

    UH – Antifreeze (other rooms, multi-system)

    What Causes This Error:

    • One indoor unit in a multi-split system detecting freezing conditions
    • Low refrigerant affecting a connected indoor unit
    • Sensor fault in one of the other rooms’ indoor units

    How to Fix The Error:

    • Check all connected indoor units for icing or airflow issues
    • Call a technician to inspect refrigerant distribution across the system
    • Ask for sensor testing on the affected indoor unit

    Troubleshoot for Most Common Daikin AC Problems

    daikin ac 3

    AC does not operate.

    Possible Causes:

    • Power failure, tripped breaker, or blown fuse
    • Power plug disconnected or ON/OFF timer set incorrectly

    What to Do: Check the power supply, breaker, and plug connection, then verify the timer settings. Contact your AC installer if the fault continues after these checks.

    Air conditioner unit does not operate.

    Possible Causes:

    • Power failure or a blown fuse
    • Incorrectly set delay timer

    What to Do: Check the power supply and replace the fuse if needed, then reset the timer. Contact your AC installer if the problem persists after these steps.

    Compressor does not operate for the first 3 minutes after startup

    Possible Causes:

    • Built-in compressor protection against frequent starting

    What to Do: Simply wait 3 to 4 minutes, as the compressor will start automatically once the protection timer clears.

    Operation stops suddenly (Operation lamp flashing)

    Possible Causes:

    • Dirty air filters restricting airflow
    • Blocked air inlet or outlet on the indoor or outdoor unit
    • Interference from lightning or radio waves

    What to Do: Clean the air filters and remove any obstructions from the inlet or outlet. Turn the breaker off and on again, and contact the service shop if the lamp keeps flashing.

    Operation stops suddenly (Operation lamp ON)

    Possible Causes:

    • Sudden voltage fluctuation triggering the AC’s protection system

    What to Do: Wait for the AC to resume operation automatically. If it does not restart on its own, check the power supply and call a technician.

    AC stops generating airflow during operation

    Possible Causes:

    • The AC reaches the set temperature and reduces airflow to avoid blowing excess cool air (heating) or raising humidity (cooling)

    What to Do: No action is needed, as airflow resumes automatically once the room temperature changes again.

    HEAT operation stops suddenly with a flowing sound

    Possible Causes:

    • The outdoor unit is removing frost buildup (defrosting)

    What to Do: Wait about 4 to 12 minutes for heating to resume once the defrosting cycle completes.

    HEAT operation cannot be selected (heat pump model)

    Possible Causes:

    • Jumper (J8) inside the unit has been cut, disabling heat mode

    What to Do: Contact the service shop to check and restore the jumper setting, as this requires a technician’s intervention.

    Hot air does not flow immediately after starting HEAT mode

    Possible Causes:

    • The system waits until the indoor heat exchanger reaches a suitable temperature before releasing air

    What to Do: Wait 1 to 4 minutes, since this is normal heat pump behavior and not a fault.

    Abnormal functioning during operation

    Possible Causes:

    • Interference from lightning or strong radio waves affecting the control system

    What to Do: Turn the breaker off, turn it back on, and try operating the AC with the remote control again.

    Outdoor fan rotates even when the AC is not operating

    Possible Causes:

    • The outdoor fan continues briefly for system protection
    • Very high outdoor temperature triggers additional fan rotation for protection

    What to Do: No action is needed, since this is normal behavior that stops automatically after about 60 seconds.

    Cooling effect is poor

    Possible Causes:

    • Dirty air filters, blocked air inlet/outlet, incorrect temperature setting, or open doors and windows

    What to Do: Clean the filters, remove any blockages, close doors and windows, and set an appropriate temperature for effective cooling.

    Heating effect is poor

    Possible Causes:

    • Very low outdoor temperature reducing heat pump capacity
    • Dirty filters or blocked airflow

    What to Do: Clean the filters and remove obstructions, and consider using a supplementary heater during extreme cold as Daikin recommends.

    Airflow is too low

    Possible Causes:

    • Dirty air filter, blocked air suction or discharge, open doors or windows, or temperature setting not high enough

    What to Do: Clean the filter, clear any obstructions, close doors and windows, and adjust the temperature setting accordingly.

    AC runs but airflow is insufficient

    Possible Causes:

    • Same causes as low airflow, including dirty filters, blocked vents, or an incorrect fan speed setting

    What to Do: Clean the filters, check the fan speed setting, and ensure the vents remain unobstructed.

    Discharge air has a bad odor

    Possible Causes:

    • Odors from cigarettes, smoke particles, cooking, or perfume settling on the indoor coil

    What to Do: Clean the air filters regularly, and get the indoor unit professionally washed if the odor persists.

    Indoor unit gives out unpleasant odor

    Possible Causes:

    • Room smells such as smoke or cooking odors get absorbed into the unit and circulate with airflow

    What to Do: Clean the filters and coil regularly, and have the indoor unit professionally cleaned if the smell continues.

    Mist comes out from the indoor unit

    Possible Causes:

    • Room air is rapidly cooled by the cold airflow during cooling operation, forming visible mist

    What to Do: No action is needed, as this is a normal effect of high humidity meeting cold airflow.

    Water flowing from the indoor unit

    Possible Causes:

    • Installation issue, high humidity, blocked drain pan or pipe, low refrigerant gas, or the AC not tilted correctly

    What to Do: Switch off the unit and call a dealer or technician to inspect the drainage system and installation angle.

    Condensation on the front air grille

    Possible Causes:

    • High air humidity after extended operation
    • Temperature set too low

    What to Do: Increase the temperature setting slightly and run the unit at high fan speed to reduce condensation.

    No drain water during cooling or dry operation (possible water leakage)

    Possible Causes:

    • Blocked drain pipe or pan, low refrigerant, or dirty cooling coil affecting condensation

    What to Do: Check the drain pipe for blockage, and call a technician to inspect the refrigerant level and coil condition.

    Moisture condenses on outdoor refrigerant piping and drips

    Possible Causes:

    • Normal condensation forming on cool outdoor piping during COOL or DRY mode
    • Frost melting into water during HEAT mode defrosting

    What to Do: No action is needed, as this is normal operation unless the dripping becomes excessive.

    Remote controller not working properly

    Possible Causes:

    • Weak or dead batteries
    • Dust on the IR sensor or obstruction between the remote and unit

    What to Do: Replace both batteries with new AAA alkaline cells and clean the signal sensor with a soft cloth.

    No remote controller signals displayed|

    Possible Causes:

    • Dying batteries causing the remote controller to malfunction

    What to Do: Replace all batteries with new AAA.LR03 (alkaline) batteries to restore normal signal transmission.

    Remote controller sensitivity is low

    Possible Causes:

    • Weak batteries or dust buildup on the signal transmitter or receiver

    What to Do: Replace the batteries and wipe the sensor area with a soft cloth to remove any dust.

    Remote controller display is dim or black|

    Possible Causes:

    • Batteries running low on power

    What to Do: Replace both batteries with new ones of the same type to restore the display.

    Remote controller display behaves abnormally

    Possible Causes:

    • Weak batteries affecting the remote’s internal circuit

    What to Do: Replace both batteries together with new AAA alkaline batteries to fix the display behavior.

    ON/OFF Timer does not operate according to the settings

    Possible Causes:

    • The ON/OFF Timer and Weekly Timer are set to the same time, causing a conflict

    What to Do: Check both timer settings and change or deactivate the Weekly Timer as needed to resolve the conflict.

    For your expired warranty Daikin AC & other appliance repair contact Daikin service centre in Kolkata for sameday doorstep repair service.

    When to Call Daikin Service Centre for Technician Visit?

    • Call the service centre right away if the power cord feels abnormally hot or looks damaged in any way.
    • An abnormal sound during operation means you should stop using the AC and contact a technician.
    • If the safety breaker, fuse, or earth leakage breaker cuts off operation frequently, the unit needs professional inspection.
    • A switch or button that often fails to work properly is a sign to call the service centre.
    • A burning smell from the AC means you should turn off the breaker and call for service immediately.
    • Water leaking from the indoor unit requires you to switch off the unit and call the dealer without delay.
    • Never attempt to repair or modify the air conditioner yourself, as incorrect work can cause electric shocks or fire.
    • Continued operation in any abnormal condition can lead to further trouble, electric shocks, or fire.
    • Always turn off the breaker first before calling the service shop for any of these issues.
    • Contact the dealer for system relocation or remodelling instead of handling it on your own.

    Daikin AC error codes help you catch problems early and understand what’s wrong. Start with simple steps like a power reset, filter cleaning, and airflow checks.

    Avoid repeated restarts if compressor, PCB, or voltage codes appear, as this can worsen the fault. If the same error returns or the AC keeps malfunctioning, contact Urban Service Plaza for professional diagnosis and repair.