Whirlpool AC Error Codes & Troubleshooting Guide [Finder Tool]
Whirlpool AC showing an error code? Use our error finder tool to see what it means, get troubleshooting steps, and know when to call an AC expert. Free checklist included.

Whirlpool AC Error Codes at a Glance
Whirlpool AC error codes appear on your indoor display, or as blinking LED patterns on the outdoor unit, whenever the system detects a malfunction. These alphanumeric codes act as an early warning system, flagging problems before they cause bigger damage.
An error code points to a faulty system, not always the exact broken part. Some causes are simple, like loose wiring or a dirty sensor. Others, like PCB or refrigerant issues, need a trained technician. This guide gives you the full error code table, common causes, safe DIY checks, and clear signs of when to call a professional.

Whirlpool AC Error Finder Tool
Choose how your AC is showing the fault, then find out what it means.
Whirlpool AC Error Code Chart: Meaning & Quick Solutions
Here is a quick-scan chart of all major Whirlpool inverter AC error codes and their fixes.
| Error Code | What It Means | Quick Fix / Next Step |
|---|---|---|
| UA | Indoor and outdoor unit mismatch | Confirm matching model/capacity, replace mismatched unit |
| E6 | Indoor-outdoor communication failure | Check wiring, power supply, inspect PCB |
| PL | Outdoor DC voltage too low | Measure DC voltage, repair/replace inverter PCB |
| PH | Outdoor DC voltage too high | Check DC output, repair/replace inverter PCB |
| F0 / P0 | Refrigerant shortage or blocked flow | Check pressure, inspect for leaks, recharge gas |
| P7 | Indoor temperature sensor fault | Check wiring, measure resistance, replace sensor |
| F2 | Indoor coil/pipe sensor fault | Reconnect sensor, check refrigerant, replace if faulty |
| F3 | Outdoor ambient sensor fault | Clean sensor, check wiring, replace if defective |
| F4 | Outdoor condenser sensor/compressor fault | Check sensor, fan, refrigerant, and compressor |
| F5 | Compressor discharge sensor fault | Clean sensor, check wiring, replace if defective |
| F6 | Outdoor suction temperature sensor fault | Check wiring, measure resistance, replace sensor |
| F7 | Outdoor ambient/condenser coil sensor fault | Check wiring, replace sensor or outdoor PCB |
| F8 | Outdoor ambient sensor fault | Inspect sensor and wiring, replace if defective |
| F9 | Outdoor DC fan motor fault | Check motor, wiring, voltage; replace fan motor |
| E0 | Outdoor PCB fault | Verify power supply, repair/replace outdoor PCB |
| E1 | Indoor fan motor fault | Check blower, wiring, PCB output; replace fan motor |
| E3 | Indoor coil/gas pipe sensor fault | Inspect sensor, measure resistance, replace sensor |
| E4 | Indoor room temperature sensor fault | Check wiring, measure resistance, replace sensor |
| EE | Indoor PCB fault | Check fan/sensors first, repair/replace indoor PCB |
| H6 | Indoor fan feedback failure | Check fan wiring, replace fan motor or inspect PCB |
| P5 | System overload protection | Check refrigerant, outdoor fan, compressor current |
| P6 | Startup failure | Verify voltage, wiring, and indoor/outdoor PCBs |
| P8 | Four-way/reversing valve fault | Check valve coil, replace valve if faulty |
Outdoor LED Blink Codes (No Indoor Display)
For units without a code display, count the LED blink pattern on the outdoor unit.
| LED1 | LED2 | LED3 | Fault |
|---|---|---|---|
| X | X | X | Normal operation |
| ★ | X | ★ | Outdoor coil temperature sensor fault |
| ★ | X | X | Compressor exhaust temperature sensor fault |
| X | X | â—‹ | Indoor-outdoor communication failure |
| ★ | ○ | X | Current overload protection |
| ★ | ○ | ★ | Maximum current protection |
| ★ | ★ | ★ | Outdoor EEPROM fault |
| X | ○ | ★ | Compressor exhaust temperature too high |
| ★ | ★ | X | Outdoor ambient temperature sensor fault |
| X | ★ | ○ | Compressor shell temperature too high |
| X | â—‹ | â—‹ | Anti-freeze/overload protection (indoor unit) |
| â—‹ | X | â—‹ | Compressor drive fault |
| ○ | ○ | ★ | Outdoor fan motor locked rotor |
| X | ★ | X | Outdoor coil anti-overload protection |
| X | â—‹ | X | IPM module protection |
| â—‹ | X | X | PFC protection |
| ★ | ★ | ○ | AC voltage higher/lower protection |
| â—‹ | â—‹ | X | DC compressor start failure |
| ★ | ○ | ○ | Outdoor ambient temp too low/high |
★ = Light on, ○ = Flashing, X = Off

Hire Our Expert Whirlpool AC Technician in Kolkata Without Advance Charges
How to Identify the Error Code on Your Whirlpool AC?

Whirlpool inverter ACs show faults in two ways. Newer models display a direct alphanumeric code on the indoor unit, while others use a blinking LED pattern on the outdoor unit’s PCB. Follow these steps to find yours:
- Check the indoor unit display first for a direct alphanumeric code, such as E6, F2, PL, or UA.
- If there is no indoor display code, open the outdoor unit and locate the three LEDs (LED1, LED2, LED3) on the PCB.
- Note whether each LED is steady ON (★), flashing (○), or OFF (X).
- Match the ON, OFF, and flashing combination to the LED blink pattern table in the chart above to find the exact fault.
- Write down the exact code or pattern before power-cycling the unit, since some faults clear on restart and become harder to diagnose later.
If you need prompt same day service contact Urban Service Plaza, the best Whirlpool AC service centre in Kolkata for out of warranty products. No advance charges and 15 days service guarantee.
Whirlpool AC Error Codes Explained: Causes and Step-by-Step Fixes?
UA – Setting Error (Indoor & Outdoor Unit Mismatch)
Possible Causes
- The indoor and outdoor units are not the same model or capacity, which prevents them from working together correctly.
- Incorrect pairing happened during the original installation, linking units that were never designed to match.
What to Do
- Verify that both the indoor and outdoor units share the exact same model and capacity rating.
- If a mismatch is confirmed, the incorrect unit will need to be replaced with a matching one.
E6 – Communication Failure
Possible Causes
- The indoor and outdoor units have lost communication with each other, often due to a faulty communication cable.
- One of the two PCBs (indoor or outdoor) may not be receiving power, or the PCB itself may have failed.
What to Do
- Check that both indoor and outdoor PCBs are receiving proper power supply.
- Inspect the communication wiring for loose, broken, or incorrectly connected wires, and measure the communication voltage, which should typically read 13–24 VDC.
- If voltage is missing at the indoor PCB, inspect it directly; if the indoor output is normal but the outdoor unit shows no signal, inspect or replace the outdoor PCB.
Voltage & Power Supply Errors (PL, PH)
PL – DC Input Voltage Too Low
Possible Causes
- The outdoor inverter PCB is failing to supply the correct DC voltage to the system.
What to Do
- Measure the DC voltage coming from the inverter PCB and inspect its output to the compressor and fan motor.
- Repair or replace the outdoor inverter PCB if the voltage reading stays low.
Safety note: voltage-related faults involve the inverter PCB and are not safe for DIY repair. Call a qualified technician.
PH – DC Input Voltage Too High
Possible Causes
- The inverter PCB is supplying excessively high DC voltage to the system.
What to Do
- Check the DC voltage output and inspect the inverter PCB for damage.
- Repair or replace the faulty PCB, since incorrect voltage can damage other components.
Safety note: voltage-related faults involve the inverter PCB and are not safe for DIY repair. Call a qualified technician.
Refrigerant-Related Errors (F0/P0)
F0 (or P0 on some models) – Refrigerant Shortage / Flow Protection
This error signals a refrigerant leak, low gas charge, or blocked refrigerant flow inside the system. Whirlpool ACs trigger this code to protect the compressor from running without proper cooling gas.
Possible Causes
- Refrigerant leakage or a low refrigerant charge.
- A blocked capillary tube or restricted refrigerant piping.
What to Do
- Check the refrigerant pressure using proper gauges.
- Inspect the entire system for leaks.
- Check for any blockage in the capillary tube or copper piping.
- Flush and vacuum the refrigerant lines before recharging.
- Recharge the refrigerant strictly to the manufacturer’s specifications.
- If you are from Kolkata or nearby areas, contact us for a low cost AC gas refilling service.
Safety note: refrigerant handling requires certified tools and training, and should never be attempted as a DIY repair.
Sensor Fault Errors (P7, F2, F3, F4, F5, F6, F7, F8)
| Code | Sensor Affected | Common Cause | Fix |
|---|---|---|---|
| P7 | Indoor temperature sensor | Faulty sensor, loose connection, or damaged wiring | Check wiring, measure resistance, replace sensor if defective |
| F2 | Indoor coil/pipe sensor | Sensor malfunction or disconnection after servicing | Reconnect sensor, verify position, check refrigerant level |
| F3 | Outdoor ambient sensor | Damaged, dirty, or disconnected sensor | Clean sensor, check wiring, replace if defective |
| F4 | Outdoor condenser sensor / compressor | Sensor fault, compressor overheating, or low refrigerant | Check sensor, fan operation, and refrigerant charge |
| F5 | Compressor discharge sensor | Sensor failure or damaged wiring | Clean sensor, check wiring, replace if defective |
| F6 | Outdoor suction sensor | Suction pipe sensor malfunction | Check wiring, measure resistance, replace faulty sensor |
| F7 | Outdoor ambient/condenser coil sensor | Sensor malfunction (model dependent) | Verify placement, measure resistance, replace sensor |
| F8 | Outdoor ambient sensor | Sensor failure | Inspect sensor and wiring, replace if defective |
Most sensor faults can be checked at home by cleaning the sensor and inspecting the wiring for damage. However, resistance testing and sensor replacement need a trained technician to avoid further PCB damage.
If you are not confident anough for fixing the Whirlpool AC by yourself, immidiately contact us for AC repairing service in Kolkata & nearby areas without any advance booking charges.
Fan Motor & PCB Errors (E0, E1, E3, E4, EE, H6, F9)
| Code | Component Affected | Common Cause | Fix |
|---|---|---|---|
| E0 | Outdoor PCB | Outdoor control board malfunction | Verify power supply, repair or replace outdoor PCB |
| E1 | Indoor fan motor | Motor failure or jammed blower | Ensure blower rotates freely, check wiring, replace motor |
| E3 | Indoor coil/gas pipe sensor | Sensor malfunction | Inspect sensor, measure resistance, replace if faulty |
| E4 | Indoor room temperature sensor | Sensor failure | Check wiring, measure resistance, replace sensor |
| EE | Indoor PCB | PCB unable to communicate or provide output | Verify fan and sensors first, repair or replace indoor PCB |
| H6 | Indoor fan feedback | Fan RPM signal missing | Check fan wiring, replace fan motor or inspect PCB |
| F9 | Outdoor DC fan motor | Fan motor failure | Check motor operation, wiring, and supply voltage |
Compressor & System Protection Errors (P5, P6, P8)
P5 – System Overload Protection
Possible Causes
- The compressor is overloaded, or the outdoor fan has stopped operating correctly.
- Low refrigerant, or the PCB is not supplying power to the compressor correctly.
What to Do
- Check the refrigerant charge and verify that the outdoor fan is operating normally.
- Inspect the compressor current and check the inverter PCB outputs for faults.
P6 – Startup Failure
Possible Causes
- The compressor or system fails to start due to a communication issue between units.
- Low mains voltage or a PCB failure can also prevent startup.
What to Do
- Verify the input voltage and check the communication wiring between units.
- Inspect both indoor and outdoor PCBs, and confirm the compressor is receiving proper power supply.
P8 – Four-Way/Reversing Valve Fault
Possible Causes
- The reversing valve is malfunctioning, which is typically noticed while the unit runs in heating mode.
What to Do
- Check the four-way valve coil and verify the valve is operating correctly.
- Replace the faulty valve or coil if testing confirms the fault.
No Indoor Display? How to Read Whirlpool Outdoor Unit LED Error Codes
Some Whirlpool AC models don’t show an alphanumeric code on the indoor display. Instead, they use three LEDs on the outdoor unit’s PCB to signal a fault.
LED Status Legend
- ★ = Steady ON
- â—‹ = Flashing
- X = OFF
How to Use This Method?
- Open the outdoor unit and observe the three LEDs (LED1, LED2, LED3) on the PCB.
- Note the exact status of each LED: ON, OFF, or flashing.
- Match the pattern to the LED blink code table in Section 3 to identify the fault.
Worked Examples
- LED1 = ★, LED2 = X, LED3 = ★ → Outdoor coil temperature sensor fault
- LED1 = X, LED2 = X, LED3 = ○ → Indoor-outdoor communication failure
- LED1 = ★, LED2 = ○, LED3 = X → Current overload protection
- LED1 = ○, LED2 = ○, LED3 = ★ → Outdoor fan motor locked rotor protection
LED patterns can vary slightly by model or PCB revision, so cross-check with the sticker on the outdoor unit’s PCB cover if available.
Which Whirlpool AC Errors Can You Fix Yourself?

Use this quick checklist to decide if your Whirlpool AC error needs a DIY check or a professional visit.
| You Can Try Yourself | Call a Professional |
|---|---|
| Power-cycle the unit for 5–10 minutes, then restart | PCB replacement or repair (indoor or outdoor) |
| Check remote batteries and settings | Refrigerant leak detection, flushing, or recharging |
| Clean visible dust from sensors | Compressor or fan motor replacement |
| Check for loose external wiring (only with power OFF) | Voltage or inverter PCB faults (PL, PH) |
| Communication wiring faults inside the unit | |
| Four-way valve replacement |
Final Thoughts
Whirlpool AC error codes are a fast diagnostic tool, not just an annoying beep. Understanding them saves you time and unnecessary repair costs.
Simple issues like loose wiring, dirty sensors, or low remote batteries can often be checked safely at home. PCB, refrigerant, and compressor faults always need certified help. Note down the exact code or LED pattern, then contact Urban Service Plaza for fast, doorstep AC diagnosis in Kolkata.