Panasonic AC Error Codes & Troubleshooting Guide [Free Tool]

Panasonic AC showing an error code? Check the full code chart, find causes fast & know if it’s DIY or needs a technician. Kolkata doorstep repair available.

panasonic ac error codes

If your Panasonic AC has stopped cooling and started flashing an LED or showing a code like E1, F3, or H11, you’re in the right place. This Panasonic AC error codes & troubleshooting guide helps you decode that signal fast. These codes point to specific parts, such as sensors, the PCB, the compressor, or the wiring between the indoor and outdoor units. However, a code doesn’t always confirm which exact part has failed.

This guide gives you a quick-reference table to spot your code instantly. You’ll also learn how to retrieve the stored error code using your remote, understand common codes with their causes and fixes, and know when a DIY step is safe versus when to call in an expert. If the problem needs professional hands, Urban Service Plaza offers doorstep AC repair across Kolkata to get your cooling back on track.

trusted source google

TL;DR:

Match your blinking LED pattern or displayed code below, then jump to that section.

  • Code starts with E or H → sensor or communication issue → check wiring and connectors first
  • Code starts with F → temperature sensor or overload protection → check filters, airflow, and EEPROM
  • Code starts with P → power or compressor protection → check voltage supply, call a technician if it repeats
  • Code disappears on its own → often a temporary protection trip, not a permanent fault

Panasonic AC error code lookup

Type your error code below to see what it means and the quick fix to try.

Complete Panasonic AC Error Code Chart (Indoor & Outdoor Units)

Panasonic labels the same fault differently depending on model age. Use the table that matches your display.

Table 1: Indoor Unit Codes (Run LED / Timer LED Based)

Error CodeLED Pattern (Run/Timer)What It MeansQuick Fix Direction
E0Run: 1 flash, Timer: OFFIndoor unit EEPROM parameter errorCall technician
E1Run: 2 flashes, Timer: OFFIndoor/outdoor communication errorCheck wiring/PCB
E2Run: 3 flashes, Timer: OFFZero-crossing signal detection errorCall technician
E3Run: 4 flashes, Timer: OFFIndoor fan speed outside normal rangeCheck fan motor
E4Run: 5 flashes, Timer: OFFRoom temperature sensor (T1) faultCheck sensor wiring
E5Run: 6 flashes, Timer: OFFEvaporator coil sensor (T2) faultCheck sensor wiring
ECRun: 7 flashes, Timer: OFFRefrigerant leakage detectedCall technician
F0Run: 1 flash, Timer: ONOverload current protectionClean filter/coil
F1Run: 2 flashes, Timer: ONOutdoor ambient sensor (T4) faultCheck sensor wiring
F2Run: 3 flashes, Timer: ONCondenser coil sensor (T3) faultCheck sensor wiring
F3Run: 4 flashes, Timer: ONCompressor discharge sensor (TP) faultCall technician
F4Run: 5 flashes, Timer: ONOutdoor unit EEPROM parameter errorCall technician
P0Run: 1 flash, Timer: FlashIPM/IGBT overcurrent protectionCall technician
P1Run: 2 flashes, Timer: FlashOver-voltage or under-voltage protectionCheck voltage supply
P2Run: 3 flashes, Timer: FlashIPM module high temperature protectionClean filter/coil
P4Run: 5 flashes, Timer: FlashInverter compressor drive errorCall technician

Table 2: Newer Model / ODU Flash Codes

ODU Flash CountIDU Display CodeFaultQuick Fix Direction
/H00No faultNo action needed
1E00Outdoor EEPROM faultCall technician
2H11Indoor to outdoor communication faultCheck wiring/PCB
4F93Compressor starting abnormalCall technician
5F02Compressor out-of-step abnormalCall technician
6F03IPM module faultCall technician
7F04Compressor shell overheat protectionClean filter/coil
8H15Compressor discharge sensor faultCheck sensor wiring
9F06Compressor suction sensor faultCheck sensor wiring
10H28Outdoor condenser sensor faultCheck sensor wiring
11H27Outdoor ambient sensor faultCheck sensor wiring
12F09Outdoor DC fan motor faultCheck fan motor
/E08Outdoor communication errorCheck wiring/PCB
13F98Outdoor AC current protectionCheck voltage supply
14F99Compressor phase current protectionCall technician
15P02Outdoor AC voltage protectionCheck voltage supply
16P03Outdoor DC voltage protectionCheck voltage supply
17F96IPM overheat protectionClean filter/coil
18F97Compressor discharge overheat protectionCall technician
19H99Indoor coil anti-freezing protectionClean filter/coil
20P07Outdoor coil overheat protection (cooling)Clean filter/coil
21P08Indoor coil overheat protection (heating)Clean filter/coil
22P09Outdoor ambient too low (cooling)Call technician
23PAOutdoor ambient too high (heating)Call technician
25EEIndoor unit EEPROM faultCall technician
26E01Indoor fan motor faultCheck fan motor
27E02Indoor PCB zero-crossing faultCall technician
28H23Indoor evaporator sensor faultCheck sensor wiring
29H14Indoor room temperature sensor faultCheck sensor wiring






    *We do not claim copyright over the logos and brand names used on our website; they are used for illustration purposes only. See disclaimer.

    How to Check Your Panasonic AC’s Error Code Using the Remote?

    panasonic ac
    1. Turn the AC off using the remote, but keep the main power supply on.
    2. Press and hold the CHECK (or CANCEL) button on the remote for about 5 seconds to enter error check mode.
    3. Press the ▲/▼ buttons (or TIMER ▲/▼) to scroll through the stored error codes.
    4. Watch for confirmation: the indoor unit beeps, typically 4 times, when it reaches the matching stored fault.
    5. Check the display for the matching error code once the beep sounds.
    6. Note that the Timer LED blinks continuously while the unit stays in error search mode.

    Note: An error code only points to the affected component. It doesn’t always confirm the exact failed part. Multiple different faults can trigger the same code, so always confirm the real cause before replacing anything.

    If you are not confident anough for fixing the Panasonic AC errors by yourself, immidiately contact Urban Service Plaza, the best AC repair service in Kolkata & nearby areas for out of warranty AC. No advance booking charges & 15 days service guarantee.

    Top Panasonic AC Error Codes: Causes and Step-by-Step Fixes

    E0 – Indoor Unit EEPROM Parameter Error

    Meaning: The indoor unit’s EEPROM parameter has failed. Run LED flashes once, Timer LED stays off.

    Possible Causes:

    • Corrupted EEPROM data
    • Faulty indoor PCB

    What to Do? Read the stored error code before disconnecting power. Check indoor PCB connectors. If the error remains, the PCB may need reprogramming or replacement by a technician.

    E1 – Indoor/Outdoor Communication Error

    Meaning: The indoor and outdoor units cannot communicate. Run LED flashes twice, Timer LED stays off.

    Possible Causes:

    • Loose or incorrect wiring between indoor and outdoor units
    • Reversed communication wires during installation
    • Damaged communication cable
    • Loose terminal connections
    • Outdoor or indoor PCB failure
    • No power supply to the outdoor unit

    What to Do? Verify wiring matches the installation diagram, check terminal screws are tight, measure communication voltage, inspect PCB connectors, and ensure the outdoor unit is receiving power. Communication errors are frequently caused by wiring mistakes rather than failed PCBs.

    Inverter and Non-inverter AC PCB repair requires highly skilled and trained technician/service engineers. Contact us for low cost AC PCB repair service in Kolkata with service guarantee.

    E2 – Zero-Crossing Signal Detection Error

    Meaning: The unit cannot detect the zero-crossing signal used to sync power supply timing. Run LED flashes three times, Timer LED stays off.

    Possible Causes:

    • Wiring or power supply issue
    • Faulty indoor PCB

    What to Do? Check indoor and outdoor wiring, inspect terminal connections, and inspect PCB connectors. Verify incoming supply voltage before assuming a PCB fault.

    E3 – Indoor Fan Speed Abnormal

    Meaning: The indoor fan is operating outside its normal speed range. Run LED flashes four times, Timer LED stays off.

    Possible Causes:

    • Fan motor fault
    • Blocked or restricted blower

    What to Do? Check indoor and outdoor fan motors for proper operation. Clean filters and heat exchangers to remove airflow restrictions, and confirm all connectors are securely fitted.

    E4 – Room Temperature Sensor (T1) Fault

    Meaning: The indoor room temperature sensor T1 is open circuit or short circuit. Run LED flashes five times, Timer LED stays off.

    Possible Causes:

    • Open circuit
    • Short circuit
    • Loose or damaged sensor wiring

    What to Do? Check sensors for proper resistance and inspect wiring. Temperature sensor errors are commonly due to open circuits, short circuits, or loose connectors.

    E5 – Evaporator Coil Temperature Sensor (T2) Fault

    Meaning: The evaporator coil temperature sensor T2 is open circuit or short circuit. Run LED flashes six times, Timer LED stays off.

    Possible Causes:

    • Open circuit
    • Short circuit
    • Loose or damaged sensor wiring

    What to Do? Check sensor resistance, inspect wiring connections, and confirm the connector is securely fitted before replacing the sensor.

    EC – Refrigerant Leakage Detected

    Meaning: The unit has detected a refrigerant leak. Run LED flashes seven times, Timer LED stays off.

    Possible Causes:

    • Refrigerant leak in the system

    What to Do? Measure refrigerant pressures and inspect for leaks. Never recharge refrigerant without first repairing any leaks.

    Never try AC refrigerant gas filling by yourself. It requires technical expertise and specific equipments. Contact our expert technician for sameday low cost AC gas filling service in and around Kolkata region.

    F0 – Overload Current Protection

    Meaning: The unit has triggered overload current protection. Run LED flashes once, Timer LED stays on.

    Possible Causes:

    • Excess load on the compressor or system
    • Restricted airflow causing overload

    What to Do? Check for airflow restrictions and clean filters and heat exchangers. Verify incoming supply voltage and confirm compressor operation.

    F1 – Outdoor Ambient Temperature Sensor (T4) Fault

    Meaning: The outdoor ambient temperature sensor T4 is open circuit or short circuit. Run LED flashes twice, Timer LED stays on.

    Possible Causes:

    • Open circuit
    • Short circuit
    • Loose or damaged sensor wiring

    What to Do? Check the sensor for proper resistance and inspect wiring connections. Replace the sensor if it fails the resistance test.

    F2 – Condenser Coil Temperature Sensor (T3) Fault

    Meaning: The condenser coil temperature sensor T3 is open circuit or short circuit. Run LED flashes three times, Timer LED stays on.

    Possible Causes:

    • Open circuit
    • Short circuit
    • Loose or damaged sensor wiring

    What to Do? Check sensor resistance and inspect wiring connections at the condenser coil before replacing the part.

    F3 – Compressor Discharge Temperature Sensor (TP) Fault

    Meaning: The compressor discharge temperature sensor TP is open circuit or short circuit. Run LED flashes four times, Timer LED stays on.

    Possible Causes:

    • Open circuit
    • Short circuit
    • Loose or damaged sensor wiring

    What to Do? Measure sensor resistance and inspect wiring connections. Verify compressor operation as part of the diagnosis.

    F4 – Outdoor Unit EEPROM Parameter Error

    Meaning: The outdoor unit’s EEPROM parameter has failed. Run LED flashes five times, Timer LED stays on.

    Possible Causes:

    • Corrupted EEPROM data
    • Faulty outdoor PCB

    What to Do? Inspect PCB connectors. Always verify the root cause before replacing expensive components such as the inverter PCB.

    P0 – IPM Malfunction or IGBT Overcurrent Protection

    Meaning: The IPM module has malfunctioned, or the IGBT has triggered overcurrent protection. Run LED flashes once, Timer LED flashes.

    Possible Causes:

    • IPM module fault
    • IGBT overcurrent condition

    What to Do? Verify incoming supply voltage and inspect PCB connectors. Protection codes often indicate abnormal operating conditions rather than permanent component failure, so confirm the root cause before replacing the IPM module.

    P1 – Over Voltage or Under Voltage Protection

    Meaning: The unit has detected voltage outside its safe operating range. Run LED flashes twice, Timer LED flashes.

    Possible Causes:

    • Over-voltage supply
    • Under-voltage supply

    What to Do? Verify incoming supply voltage is stable and within range before assuming a component fault.

    P2 – High Temperature Protection of IPM Module

    Meaning: The IPM module has overheated and triggered protection. Run LED flashes three times, Timer LED flashes.

    Possible Causes:

    • IPM module overheating

    What to Do? Clean filters and heat exchangers to improve airflow and cooling around the module, and check for airflow restrictions.

    P4 – Inverter Compressor Drive Error

    Meaning: The inverter compressor drive circuit has an error. Run LED flashes five times, Timer LED flashes.

    Possible Causes:

    • Compressor drive fault
    • IPM or inverter circuit issue

    What to Do? Verify compressor operation and inspect PCB connectors. Confirm the root cause before replacing the compressor or inverter PCB, as these are expensive components.

    H00 – No Fault

    Meaning: No fault is present in the system.

    Possible Causes:

    • Not applicable; this code confirms normal operation

    What to Do? No action needed.

    E00 – Outdoor EEPROM Fault

    Meaning: The outdoor unit’s EEPROM has failed (ODU flash count: 1).

    Possible Causes:

    • Corrupted EEPROM data
    • Faulty outdoor PCB

    What to Do? Inspect PCB connectors. Verify the root cause before replacing the outdoor PCB.

    H11 – Indoor to Outdoor Communication Fault

    Meaning: Communication between the indoor and outdoor units has failed (ODU flash count: 2).

    Possible Causes:

    • Loose or incorrect wiring between indoor and outdoor units
    • Reversed communication wires during installation
    • Damaged communication cable
    • Loose terminal connections
    • Outdoor PCB failure
    • Indoor PCB failure
    • No power supply to outdoor unit

    What to Do? Verify wiring matches the installation diagram, check terminal screws are tight, measure communication voltage, inspect PCB connectors, and ensure the outdoor unit receives power. A common installation mistake is connecting the earth wire to the communication terminal or swapping communication wires. Correcting the wiring immediately clears the H11 error.

    F93 – Compressor Starting Abnormal

    Meaning: The compressor fails to start normally (ODU flash count: 4).

    Possible Causes:

    • Compressor start fault

    What to Do? Verify compressor operation and check incoming supply voltage. Confirm root cause before replacing the compressor.

    F02 – Compressor Out-of-Step Abnormal

    Meaning: The compressor has lost synchronization during operation (ODU flash count: 5).

    Possible Causes:

    • Compressor drive fault

    What to Do? Verify compressor operation and inspect PCB connectors related to the drive circuit.

    F03 – IPM Module Fault

    Meaning: The IPM module has failed (ODU flash count: 6).

    Possible Causes:

    • IPM module fault

    What to Do? Inspect PCB connectors. Verify the root cause before replacing the IPM module, as it is an expensive component.

    F04 – Compressor Shell Temperature Overheat Protection

    Meaning: The compressor shell has overheated, triggering protection (ODU flash count: 7).

    Possible Causes:

    • Compressor overheating

    What to Do? Check for airflow restrictions, clean filters and heat exchangers, and verify compressor operation.

    H15 – Compressor Discharge Temperature Sensor Fault

    Meaning: The compressor discharge temperature sensor has failed (ODU flash count: 8).

    Possible Causes:

    • Faulty compressor discharge temperature sensor
    • Open circuit
    • Short circuit
    • Loose sensor connector
    • Damaged wiring

    What to Do? Measure sensor resistance, check connector seating, and inspect the wiring harness. Replace the sensor if defective.

    F06 – Compressor Suction Temperature Sensor Fault

    Meaning: The compressor suction temperature sensor has failed (ODU flash count: 9).

    Possible Causes:

    • Open circuit
    • Short circuit
    • Loose or damaged sensor wiring

    What to Do? Check sensor resistance and inspect wiring connections before replacing the sensor.

    H28 – Outdoor Condenser Temperature Sensor Fault

    Meaning: The outdoor heat exchanger (condenser) temperature sensor has failed (ODU flash count: 10).

    Possible Causes:

    • Heat exchanger sensor failure
    • Open circuit
    • Short circuit
    • Connector not seated properly

    What to Do? Measure sensor resistance, check the sensor’s location on the condenser coil, and inspect wiring. Replace the sensor if necessary.

    H27 – Outdoor Ambient Temperature Sensor Fault

    Meaning: The outdoor ambient temperature sensor has failed (ODU flash count: 11).

    Possible Causes:

    • Failed outdoor ambient sensor
    • Open circuit
    • Short circuit
    • Loose connector

    What to Do? Measure sensor resistance and check wiring continuity. Replace the faulty sensor.

    F09 – Outdoor DC Fan Motor Fault

    Meaning: The outdoor DC fan motor has failed (ODU flash count: 12).

    Possible Causes:

    • Fan motor fault

    What to Do? Check indoor and outdoor fan motors and confirm all connectors are securely fitted.

    E08 – Outdoor Communication Error

    Meaning: The outdoor unit is experiencing a communication error.

    Possible Causes:

    • Wiring fault between units
    • Faulty outdoor PCB

    What to Do? Check indoor and outdoor wiring, inspect terminal connections, and confirm the outdoor unit receives power.

    F98 – Outdoor AC Current Protection

    Meaning: The outdoor unit has triggered AC current protection (ODU flash count: 13).

    Possible Causes:

    • Abnormal AC current draw

    What to Do? Verify incoming supply voltage and check for airflow restrictions affecting compressor load.

    F99 – Compressor Phase Current Protection

    Meaning: The compressor has triggered phase current protection (ODU flash count: 14).

    Possible Causes:

    • Abnormal compressor phase current

    What to Do? Verify compressor operation and check incoming supply voltage before replacing components.

    P02 – Outdoor Unit AC Voltage Protection

    Meaning: The outdoor unit has detected AC voltage outside its safe range, either too high or too low (ODU flash count: 15).

    Possible Causes:

    • Over-high or over-low AC voltage supply

    What to Do? Verify incoming supply voltage is stable and within range.

    P03 – Outdoor Unit DC Voltage Protection

    Meaning: The outdoor unit has detected DC voltage outside its safe range, either too high or too low (ODU flash count: 16).

    Possible Causes:

    • Over-high or over-low DC voltage

    What to Do? Verify incoming supply voltage and inspect PCB connectors.

    F96 – IPM Overheat Temperature Protection

    Meaning: The IPM module has overheated (ODU flash count: 17).

    Possible Causes:

    • IPM module overheating

    What to Do? Clean filters and heat exchangers to improve airflow and check for restrictions around the module.

    F97 – Compressor Discharge Temperature Overheat Protection

    Meaning: The compressor discharge temperature has exceeded its safe limit (ODU flash count: 18).

    Possible Causes:

    • Compressor discharge overheating

    What to Do? Measure refrigerant pressures, check for airflow restrictions, and verify compressor operation.

    H99 – Cooling Indoor Unit Coil Anti-Freezing Protection

    Meaning: The indoor coil has triggered anti-freezing protection during cooling mode (ODU flash count: 19).

    Possible Causes:

    • Indoor coil freezing risk

    What to Do? Check for airflow restrictions and clean filters and the evaporator coil.

    P07 – Cooling Outdoor Coil Overheat Protection

    Meaning: The outdoor coil has overheated during cooling mode (ODU flash count: 20).

    Possible Causes:

    • Outdoor coil overheating

    What to Do? Clean filters and heat exchangers and check for airflow restrictions around the outdoor coil.

    P08 – Heating Indoor Coil Overheat Protection

    Meaning: The indoor coil has overheated during heating mode (ODU flash count: 21).

    Possible Causes:

    • Indoor coil overheating

    What to Do? Check for airflow restrictions and clean filters and heat exchangers.

    P09 – Cooling Outdoor Ambient Temperature Over-Low Protection

    Meaning: The outdoor ambient temperature is too low for cooling mode operation (ODU flash count: 22).

    Possible Causes:

    • Outdoor ambient temperature below safe operating range

    What to Do? Verify outdoor ambient temperature conditions. This protection code often indicates an abnormal operating condition rather than a permanent component failure.

    PA – Heating Outdoor Ambient Temperature Over-High Protection

    Meaning: The outdoor ambient temperature is too high for heating mode operation (ODU flash count: 23).

    Possible Causes:

    • Outdoor ambient temperature above safe operating range

    What to Do? Verify outdoor ambient temperature conditions before assuming a component fault.

    EE – Indoor Unit EEPROM Fault

    Meaning: The indoor unit’s EEPROM has failed (ODU flash count: 25).

    Possible Causes:

    • Corrupted EEPROM data
    • Faulty indoor PCB

    What to Do? Inspect PCB connectors. Verify the root cause before replacing the indoor PCB.

    E01 – Indoor Fan Motor Fault

    Meaning: The indoor fan motor has failed (ODU flash count: 26).

    Possible Causes:

    • Fan motor fault

    What to Do? Check indoor and outdoor fan motors and confirm all connectors are securely fitted.

    E02 – Indoor PCB Zero-Crossing Fault

    Meaning: The indoor PCB cannot detect the zero-crossing signal (ODU flash count: 27).

    Possible Causes:

    • Wiring or power supply issue
    • Faulty indoor PCB

    What to Do? Check indoor wiring and inspect PCB connectors. Verify incoming supply voltage before replacing the PCB.

    H23 – Indoor Evaporator Temperature Sensor Fault

    Meaning: The indoor evaporator temperature sensor has failed (ODU flash count: 28).

    Possible Causes:

    • Open circuit
    • Short circuit
    • Loose or damaged sensor wiring

    What to Do? Check sensor resistance and inspect wiring connections before replacing the sensor.

    H14 – Indoor Room Temperature Sensor Fault

    Meaning: The indoor room temperature sensor has failed (ODU flash count: 29).

    Possible Causes:

    • Open circuit
    • Short circuit
    • Loose or damaged sensor wiring

    What to Do? Check sensor resistance and inspect wiring connections. Temperature sensor errors are commonly due to open circuits, short circuits, or loose connectors.

    What You Should Know Before Fixing a Panasonic AC Error Yourself?

    panasonic ac 2
    Don’t Assume / Don’t DoWhy It Matters
    Never recharge refrigerant without repairing leaks firstCauses repeat failure and wastes gas and money
    Don’t assume PCB failure from a communication errorMost communication errors are wiring mistakes, not failed boards
    Don’t ignore loose connectors on temperature sensorsOpen, short, or loose connections are the most common sensor-error cause
    Don’t replace the compressor, inverter PCB, or IPM immediatelyConfirm the root cause first, since these are expensive parts
    Don’t panic over every P-series or F-series codeMany clear on their own and reflect abnormal operating conditions, not permanent damage

    Wrapping Up

    Panasonic error codes fall into clear families: sensor faults, communication issues, refrigerant problems, and power or compressor protection. Checking the stored code via remote and matching it to the table above remains the fastest first step.

    Some codes are safe to inspect at home, but refrigerant, PCB, and compressor-related codes call for a certified technician. If the error persists, Urban Service Plaza offers doorstep diagnosis and repair across Kolkata.